Design and function
Special parameters (advanced settings)
88
099-005403-EW501
10.2.2022
5.11.3.2 Program "0", releasing the program block (P2)
The program P0 (manual setting) is blocked. Only operation with P1-P15 is possible, irrespective of the
key switch position.
5.11.3.3 Display mode for Up/Down welding torch with one-digit 7-segment display (P3)
Normal display:
• Program mode: Program number
• Up/down operation: Welding power (0=minimum current/9=maximum current)
Toggling display:
• Program mode: Program number and welding procedure (P=pulse/n=not pulse) are toggled
• Up/down operation: Welding power (0=minimum current/9=maximum current) and symbol for up/down
operation are toggled
5.11.3.4 Program limit (P4)
Program selection can be limited with the special parameter P4.
• The setting is adopted for all JOBs.
• Program selection depends on the position of the "welding torch function" changeover
switch
> see 5.3.16 chapter
.
Programs can only be switched when the changeover switch is in the "program" position.
• Programs can be switched by means of a connected remote control or special welding torch.
• If a special welding torch or a remote control is not connected, it is only possible to switch programs by
means of the "arc length correction/select welding program" rotary dial
> see 4.3 chapter
.
5.11.3.5 Special cycle in the operating modes special latched and non-latched (P5)
With the special sequence activated, the start of the welding process changes as follows:
Sequence for special non-latched mode/special latched mode:
• Start program "P
START
"
• Main program "P
A
"
Sequence for special non-latched mode/special latched mode with custom sequence activated:
• Start program "P
START
"
• Reduced main program "P
B
"
• Main program "P
A
"
Enabling special JOBs SP1 to SP3 (P6)
Phoenix Expert machine series:
The welding task is set at the power source control; refer to the relevant system documentation.
If required, the predefined special welding tasks SP1 = JOB 129 / SP2 = JOB130 / SP3 = JOB 131 only
can be selected at the wire feeder control. The special JOBs are selected by pressing the welding task
selection push-button for a longer period. The special JOBs are switched by pressing the push-button
briefly.
When the key switch is in the position , JOB switching is locked. This lock can be removed for the spe-
cial JOBS (SP1-SP3).