Functional characteristics
Machine configuration menu
099-0M37XS-EW501
31.8.2022
39
Display
Setting/selection
Time-based power-saving mode
> see 5.10 chapter
Time to activation of the power-saving mode in case of inactivity.
Setting
= disabled or numerical value 5-60 min..
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!
5.9.2 Aligning the cable resistance
The resistance value of the cables can be set directly or it can be adjusted through the power source. The
power source cable resistance value is set to 8 mΩ when delivered. This value corresponds to an earth
cable length of 5 m, an intermediate hose package length of 1.5 m and a water-cooled welding torch
length of 3 m. A +/- welding voltage correction is therefore required to optimise the welding properties for
other hose package lengths. By realigning the cable resistance, the voltage correction value can be set
close to zero again. The electric cable resistance should be realigned whenever an accessory component
such as the welding torch or the intermediate hose package has been changed.
2
3
4
1
l
0
50mm
l
0
B
A
+
Figure 5-27