Functional characteristics
Special parameters (advanced settings)
36
099-0M37XS-EW501
31.8.2022
5.8 Special parameters (advanced settings)
Special parameters (P1 to Pn) are applied for customer-specific configuration of machine functions. This
allows the user maximum flexibility in optimising their requirements.
These settings are not configured directly on the machine control since a regular setting of the parame-
ters is generally not required. The number of selectable special parameters can deviate between the ma-
chine controls used in the welding system (also see the relevant standard operating instructions).
If required, the special parameters can be reset to the factory settings
> see 5.8.7 chapter
.
5.8.1 Selecting, changing and saving parameters
+
A
B
B
A
B
Figure 5-24
Display
Setting/selection
Wire inching / wire return ramp time
0 = -------- normal inching (10 s ramp time)
1 = -------- fast inching (3 s ramp time) (ex works)
Tapping start for latched and special latched operation
0 = -------- no 4-cycle inching start
1 = -------- 4-cycle inching start possible (ex works)
HOLD function
0 = -------- HOLD values are not displayed
1 = -------- HOLD values are displayed (Ex works)