5.10.3.21 Correction or nominal voltage display (P24)
When setting the arc correction using the right-hand rotary knob the display will either show the correction
v- 9.9 V (ex works) or the absolute nominal voltage.
5.10.3.22 JOB selection in Expert mode (P25)
The special parameter P25 can be used to specify whether the special JOBs SP1/2/3 or the welding job
selection according to the JOB list can be selected on the wire feeder.
5.10.3.23 Nominal value wire heater (P26)
Preheating the welding wire in the temperature range of 25°C - 50°C. Setting 45°C ex works.
5.10.3.24 Mode switching at welding start (P27)
With the selected
4-cycle-Special mode, the user can determine by the time of the torch trigger operation
in which operating mode (4-cycle or 4-cycle-Special) the program sequence shall be carried out.
Hold torch trigger (longer than 300 ms):
Program sequence with
operating mode
4-cycle-Special
(standard).
Tap torch trigger: Device changes to operating mode
4-cycle.
5.10.3.25 Error threshold electronic gas flow control (P28)
The set percentage value is the error threshold; if it is undershot or exceeded, an error
message
> see 7.2 chapter
is displayed
.
5.10.3.26 Units system (P29)
Function not active
• Metric metric units are displayed.
Function active
• Imperial units are displayed.
5.10.3.27 Selection option
– Program sequence with welding power rotary knob (P30)
Function not active
• The rotary knob is locked, use the welding parameters push-button to select the welding parameters.
Function active
• Rotary knob can be used to select the welding parameters.