Design and function
Special parameters (advanced settings)
099-005507-EW501
13.09.2018
83
5.10.3.11 JOB list switching (P12)
Value Name
Explanation
0
Task-based
JOB list
JOB numbers are sorted by welding wires and shielding gases. When
selecting, the JOB numbers may be skipped.
1
Real JOB list
JOB numbers correspond to the actual memory cells. Every job can
be selected, there will be no memory cells if the selection will be
skipped.
2
Real JOB list,
JOB switching active
Like real JOB list. In addition JOB switching with appropriate
accessory components such as a function torch is possible.
Creating user-defined JOB lists
An associated memory area, in which switching with accessory components such as a function
torch between JOBs is possible, is created.
• Set special parameters P12 to "2".
• Set switch "Program or Up/Down Function" to “Up/Down" position.
• Select existing JOB, which comes as close as possible to the desired result.
• Copy JOB to one or more destination JOB numbers.
If JOB parameters still need to be adjusted, select destination JOBs one after the other and adjust
parameters individually.
• Special parameters P13 to the lower limit and
• Adjust special parameters P14 to the upper limit of the destination JOBs.
• Set switch "Program or Up/down function" to position "Program".
With the accessory component JOBs can be switched in the specified range.
Copying JOBs, "Copy to" function
The possible target range is between 129 - 169.
• First configure special parameter P12 to P12 = 2 or P12 = 1!
3s
5s
Figure 5-78