Maintenance, care and disposal
Maintenance schedule
099-005630-EW501
02.03.2021
39
Figure 6-9
• Reconnect all four power lines to the main switch (note inputs / outputs).
• Reinstall the side panels and secure with the screws.
• Check the machine according to applicable regulations.
6.3.4 Heat exchanger (torch cooling)
WARNING
Risk of injury due to insufficient training!
An appropriate training is necessary for the following maintenance steps to avoid inju-
ries.
• This maintenance step may only be carried out by trained and authorized specialist staff.
• Observe warnings and maintenance instructions at the beginning of this chapter!
Figure 6-10
• Switch off the machine and disconnect the mains plug. Remove the screws of the side panels. Re-
move side panels (fold out sideways at the bottom and pull out downwards).
• Clean the machine fan with compressed air free of oil and water.
Block the fan wheel of the machine fan mechanically (the machine fan may over-rotate due to the
compressed air and be damaged as a result)!