5.11 Special parameters (advanced settings)
Special parameters (P1 to Pn) are applied for customer-specific configuration of machine functions. This
allows the user maximum flexibility in optimising their requirements.
These settings are not configured directly on the machine control since a regular setting of the
parameters is generally not required. The number of selectable special parameters can deviate between
the machine controls used in the welding system (also see the relevant standard operating instructions).
If required, the special parameters can be reset to the factory settings
> see 5.11.1.1 chapter
.
5.11.1 Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off machine at the main switch.
• Press and hold the "left parameter selection" button and switch the machine on again at the
same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "welding parameter setting" rotary dial.
• Set or change the parameters by turning the "arc length correction/select welding program"
rotary dial.
EXIT (Exit the menu)
• Press the "right parameter selection" button (switch machine off and on again).
ENTER
B
A
A
l
0
+
EXIT
B
NAVIGATION
A
B
A
Figure 5-73
Display
Setting/selection
Ramp time for wire inching
0 = ------- normal inching (10s ramp time)
1 = ------- fast inching (3s ramp time) (Ex works)
Block program "0"
0 = ------- P0 enabled (Ex works)
1 = ------- P0 blocked
Display mode for Up/Down welding torch with one-digit 7-segment display (two
keys)
0 = ------- normal display (ex works) program number/welding power (0
–9)
1 = ------- display toggles between program number/welding type