background image

*Please see separate Smart Relay manual for 

complete instructions. The Smart Switch 

Sub-Assembly is an accessory part of In-wall 

Relay Switch and only functional when 

connected with the Smart Relay.

Rev. A-032021

P/N SS01

Instruction

Manual

Smart Switch ×1

Instruction Manual ×1

Caution: Read this manual before attempting to 

install the device! Using this product in a manner 

other than intended voids your warranty. Further, Evvr 

is NOT liable for any damage incurred with the misuse 

of this product.

Warning: Turn OFF electrical power from the breaker 

box or electrical service panel before installing or 

servicing this product. Improper use or installation 

can cause SERIOUS INJURY, DEATH, or LOSS/DAM-

AGE OF PROPERTY.
Caution: Use this product in an indoor environment.

Caution: All installations of this device should be 

performed by a qualified or licensed electrician!
Caution: Product must be installed on a 10A line.

Installation Instructions

Product Introduction

Smart Switch Sub-Assembly is an optional compo-

nent of the In-Wall Relay Switch when they are used 

together. The Smart Switch Sub-Assembly is 

designed to allow mechanical switch panels to work 

with switch commands from the network. For 

example, after turning off the lights with a mechani-

cal switch panel, you can turn on the lights through 

network commands.

One Smart Relay can be connected to one or a series 

Smart Switch Sub-Assembly (multiple point control).

One Smart Switch Sub-Assembly can be connected 

to two circuits of loads, each of which must use one 

Smart Relay.

TECHNICAL SPECIFICATIONS

Model number

SS01

Input Voltage

AC 85V~245V

Max. Load Power

AC 110V/300W

AC 220V/600W

Min. Load Power

No limit

Supported Switch Type Toggle, Momentary

Operating Temperature 0~40°C

(32°~104°F)

Relative Humidity

5~85% RH

Product Size (L*W*H)

33.5mm * 28.2mm * 17.3mm 

(1.32in. x 1.11in. x 0.68in.)

Complete Accessories Include

Panel Connector Wire ×2

Fastening screws

Panel Connection port

Wire Connection port

SW1: External switch control for load

L  : Power input for live wire
L1: Power output for live wire
L2: Power output for live wire

SW2: External switch control for load

NOTE:

‘SW1’ controls the ‘L1’ 

‘SW2’ controls the ‘L2’

With Smart Switch Sub-Assembly you can control Smart 

Relay using traditional switch panel. 

Smart Switch Sub-Assembly compatible with 1/2 gang 

switch panel, and two Smart Switch Sub-Assemblies can 

be installed to support 3/4 gang switch panel. 

The diagram to the right shows the connection of wires.

SW1

SW2

If the Smart Switch Sub-Assembly and Smart Relay are connected correctly, it should look like diagram 

below. For more instructions on how to install the Smart Relay, please see the Smart Relay Manual.

In a single switch environment, please choose one of the installation methods to install on the L1 

line according to your actual installation environment.

1

Connect the wires to the switch panel

2

Overall Diagram

Wiring a Single Light Switch

In-Wall Relay Switch

Smart Switch Sub-Assembly

 Instruction Manual

N

L

L OUT

L

LOAD

SW1

N

N

L

L OUT

L

LOAD

SW1