Measurement inputs
In principle, the following types of sensor measuring module or
retrofit kits can be installed at the module slot: The sensor
measuring modules are only supported in applications 1 and 2:
Please note
As 3-electrode cell, DEPOLOX
®
5, DEPOLOX
®
Pool, glass
electrodes or DEPOLOX
®
4 can be connected. All of these sensor
measuring modules are available with the „Process Control“ option
(PC).
When the unit is switched on, the menus are initialized according
to the installed sensor module. Even if the sensor modules are
changed at a later date, the user menus are automatically
initialized when the unit is switched on. If no sensor measuring
module is installed in unit version 1, the message „No
measurement available“ appears. When delivered from the
factory, the SFC is set to application 2. Unit version 2 can only
operate in application 3.
The sensor measuring module should be considered as the main
measurement, and control functions such as single feed forward,
single feedback closed loop control, and compound loop are
supported depending on the Process Control option. No controller
output is available for application 1.
DES
-
for 3-electrode cell
DES
-
for 3-electrode cell with PT 100 temperature
option
DES
-
for free chlorine (FC1/FC2), chlorine dioxide
(CD7), ozone (OZ7), and total chlorine (TC1/
TC3) membrane sensors
DES
-
for Micro 2000 with PT 1000
DES
-
for DEOX 2000 with PT 1000
pH
-
pH value
mV
-
Redox value
F
-
-
Fluoride value
mS
-
Conductivity
mA/V
-
Input module
Summary of Contents for WALLACE & TIERNAN SFC
Page 1: ...WALLACE TIERNAN MEASURING AND CONTROL SYSTEM SFC from version V 3 08 INSTRUCTION MANUAL...
Page 2: ...2 WT 050 590 000 DE IM 0719 SFC Please note Original instruction manual...
Page 40: ...40 WT 050 590 000 DE IM 0719 Description SFC 3...
Page 118: ...118 WT 050 590 000 DE IM 0719 Functions SFC 4...
Page 121: ...SFC Installation 5 121 Top hat rail assembly...
Page 122: ...122 WT 050 590 000 DE IM 0719 Installation SFC 5 Wall mounting assembly...
Page 123: ...SFC Installation 5 123 Top hat rail assembly...
Page 124: ...124 WT 050 590 000 DE IM 0719 Installation SFC 5 Wall mounting assembly...
Page 125: ...SFC Installation 5 125 Control cabinet installation assembly...
Page 126: ...126 WT 050 590 000 DE IM 0719 Installation SFC 5 Control cabinet installation assembly...
Page 127: ...SFC Installation 5 127 Installation of the front panel on the control cabinet...
Page 156: ...156 WT 050 590 000 DE IM 0719 Installation SFC 5...
Page 218: ...218 WT 050 590 000 DE IM 0719 Operation SFC 6...
Page 232: ...232 WT 050 590 000 DE IM 0719 Maintenance SFC 7...
Page 266: ...266 WT 050 590 000 DE IM 0719 Complete Units Retrofit Kits and Spare Parts SFC 8...
Page 274: ...274 WT 050 590 000 DE IM 0719 Declarations and certificates SFC 10...
Page 275: ...SFC Declarations and certificates 10 275 10 2 Certificate of Compliance...
Page 276: ...276 WT 050 590 000 DE IM 0719 Declarations and certificates SFC 10...
Page 284: ...284 WT 050 590 000 DE IM 0719 Settings Table SFC 11...