Overview

Heat Pump HVAC System Wiring

Terminal Marking

Meaning

Typical Wire Color

Record the old thermostat wire 
connections and 
terminal marking here

C

24VAC Common

Blue

R

24VAC Return

Red

G

Fan

Green

W or W1

Aux Heat

White

Y or Y1

Compressor stage 1

Yellow

O (or B*)

Change Over Valve

Orange (brown*)

Y2

Compressor stage 2

Black

If you have a terminal marked “B” with a brown wire attached to it, that means you have a changeover (C/O) with heating 
type heat pump system.  Be sure to set the change over type in the 

Installer Settings

 menu to 

C/O Type: w/ Heat

.  

Otherwise, leave it set to 

w/ Cool

.

Standard HVAC System Wiring

Terminal Marking

Meaning

Typical Wire Color

Record the old thermostat wire 
connections and 
terminal marking here

C

24VAC Common

Blue

R

24VAC Return

Red

G

Fan

Green

W or W1

Heat stage 1

White

Y or Y1

Cool stage 1

Yellow

W2

Heat stage 2

Orange

Y2

Cool stage 2

Black

Summary of Contents for T-100-R

Page 1: ...T 100 R Installation Guide ...

Page 2: ...ents T 100 R Z Wave Thermostat 3 4 HVAC System Setup 6 Installer Settings Menu Items 7 9 Installer Settings Summary 10 11 Overview Installation Standard Gas Elec HVAC System Wiring 13 Heat Pump HVAC System Wiring 14 Wiring ...

Page 3: ...ting systems 1 stage heating and cooling 2 stage heating and cooling Heat Pump systems 1 stage heating and cooling 2 stage heating and cooling 2nd or 3rd stage Auxilary heating heat strips Do NOT use for line voltage controls 120 240VAC STOP Before removing your existing thermostat be sure to label the wires with the terminal markings on the old thermostat and record them below Overview ...

Page 4: ...have a terminal marked B with a brown wire attached to it that means you have a changeover C O with heating type heat pump system Be sure to set the change over type in the Installer Settings menu to C O Type w Heat Otherwise leave it set to w Cool Standard HVAC System Wiring Terminal Marking Meaning Typical Wire Color Record the old thermostat wire connections and terminal marking here C 24VAC Co...

Page 5: ...installation ...

Page 6: ...will need to know the following information to correctly configure the thermostat The HVAC setup is in the Mechanical Settings menu screen HVAC system type What type HVAC system do you have Standard or Heat pump For Standard systems Fan Type Do you have Gas heat or Electric heat For Heat Pump systems Change over valve or reversing valve type Does your system change over with cooling operation or w...

Page 7: ...ing N Test mode off Normal system delays CAUTION in test mode all system safety delays are shorten Do not operate the system compressor in test mode Disconnect Y1 or Y2 outputs if using test mode on a live system Range Y or N Default N System Settings Submenu Sets the HVAC operational settings below Mechanical Settings Submenu Sets the HVAC system type and configuration Type Range Gas Elec or Heat...

Page 8: ...etpoints Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation Same for setting the heating setpoint above the cooling setpoint it will PUSH the cooling setpoint up to maintain this separation Heating Delta Stage 1 ON Range 1 8 degrees Default 1 Sets the delta from setpoint that stage 1 heating starts Heating Delta S...

Page 9: ...alue Will not ramp or accept setpoints lower than this minimum Range 44F to 113F 6C 45C Default 60F 15C Minimum Run Time MRT Sets the minimum run time before a heating cooling cycle can turn off Sets heating cooling cycle time Prevents rapid cycling Range 1 9 minutes Default 3 Minimum Off Time MOT Sets the minimum off time before another heating cooling cycle can begin Provides compressor short cy...

Page 10: ...pe w Heat or w Cool w Cool 2nd Stage Heat Y or N N Aux Heat Y or N Y 2nd Stage Cool Y or N N H C Delta 3 15 deg 3 Heat Delta Stage 1 On 1 8 1 Heat Delta Stage 1 Off 0 8 0 Heat Delta Stage 2 On 1 8 2 Heat Delta Stage 2 Off 0 8 0 Heat Delta Stage 3 On 1 8 3 Heat Delta Stage 3 Off 0 8 0 Cool Delta Stage 1 On 1 8 1 Cool Delta Stage 1 Off 0 8 0 Cool Delta Stage 2 On 1 8 2 Cool Delta Stage 2 Off 0 8 0 M...

Page 11: ...enu Maint Interval Disabled 100 4000 hrs 3000 Screen Timeout to minimized screen 0 20 120 sec 0 0 off will not timeout F C Mode F or C F Sensor Calibration Submenu Internal 7 to 7 0 Backlite Display Submenu Backlight Timeout 0 20 120 0 0 backlite off Backlight On Brightness 0 100 100 Backlight Off Brightness 0 100 0 Contrast 0 20 14 ...

Page 12: ...wiring ...

Page 13: ...is set to N If you have a two stage cooling system set to Y to enable Setup Standard HVAC System G Fan W1 Heat Stage 1 Y1 Compressor Stage 1 R 24VAC Return C 24VAC Common Thermostat Connection Y2 Compressor Stage 2 W2 Heat Stage 2 Optional 24R Connection for single transformer HVAC Systems RC and RH are jumpered together on thermostat board Cut RC RH jumper JP1 for separate heating cooling transfo...

Page 14: ...Back Heat Pump HVAC System Thermostat Connection G Fan W1 Aux Heat Y1 Compressor Stage 1 R 24VAC Return C 24VAC Common Y2 Compressor Stage 2 O Change Over Valve For Heat Pump systems connect the 24R connection to either the 24RC or 24RH Y1 G Y2 RS2 RS2 RSC HC 24RC W1 24RH W2 O RS1 RS1 RSC H1 24C Cooling 24V Fan Cooling stage 1 Cooling stage 2 Remote Sensor 2 Remote Sensor 2 Sensor shield Humidity ...

Page 15: ...CORPORATE 16 South Maryland Ave Port Washington NY 11050 855 750 9090 info eguestcontrols com ...

Page 16: ...www evolvecontrols com ...

Reviews: