![Evolution evotherm EFI Ultra V30T Installation And Operation Manual Download Page 12](http://html1.mh-extra.com/html/evolution/evotherm-efi-ultra-v30t/evotherm-efi-ultra-v30t_installation-and-operation-manual_2446912012.webp)
9
2.4. Parameter of the Unit
Table-1
Model
EFI Ultra V30T
Air Temperature: 27
℃, inlet/outlet water tem perature: 26℃/28℃,
humidity 80%
Heating capacity (kW)
11.7-29.81
Power input (kW)
0.79-4.45
COP
14.81-6.7
Air Temperature: 15
℃, inlet/outlet water tem perature: 26℃/28℃,hum idity 70%
Heating capacity (kW)
8.96-22.35
Power input (kW)
1.31-4.50
COP
6.84-4.96
Air Temperature: 35
℃, inlet/outlet water tem perature: 28℃/26℃
Cooling capacity (kW)
5.56-17.4
Power input (kW)
1.11-6.7
EER (kW)
5.01-2.64
Power supply (V/Ph/Hz)
380-415V/3N~/50Hz
Max power input (kW)
7.3
Max current (A)
13.0
Setting temperature range (Heating)
15
℃
~
40
℃
Setting temperature range (Cooling)
8
℃
~
28
℃
Running temperature range
-10
℃
~
43
℃
Refrigerant
R32
Compressor
MITSUBISHI ELECTRIC ( DC inverter)
Air side heat exchanger
Hydrophilic fin and tube
Water side heat exchanger
Titanium PVC Tank
Water flow (LPM)
190
Net dimension LxWxH (mm)
900x812x1054
Water pipe connection (mm)
40/50
Net weight (kg)
137
Noise level dB(A)
46-68
Water proof level
IPX4
3. INSTALLATION AND CONNECTION
WARNING:
The heat pump must be installed by a professional team. The users
are not qualified to install by themselves, otherwise the heat pump might be
damaged and risky for users’ safety.
This section is provided for information purposes only and must be checked and
adapted if necessary according to the actual installation conditions.