Evolution DWP1000 Original Manual Download Page 11

125

www.evolutionbuild.com

®

SV

SK

RU

PT

PL

NO

NL

IT

GB

FR

FI

ES

EL

DE

DA

CZ

Fig 1a 

 

(LH view of 3 locating pins)

Fig 1b 

 

(RH view of 3 locating pins)

Fig 1c 

 

(showing 2 rear stabiliser pins)

ASSEMBLY

1. Connecting the DWP100 

Water Pump to the Evo-System

 

Engine

Note:

 Your Evolution Pump is designed to be connected 

to and powered by the Evo-System Engine. Do not try to 

connect this machine to any other power source. Your Evo-

System Engine has a unique patented coupling that enables 

a variety of  Evo-System accessories to be connected to and 

be driven by this machine. 

This coupling is engineered to very fine tolerances and must 

be kept clean and free from dirt, debris etc.

A cover for coupling protection is provided with each 

accessory and should be used whenever the accessory is 

‘remote’ from the engine.

If you experience difficulty in accessory connection, it could be 

because the accessory location pins, or the annuli of either the 

accessory or the engine are contaminated or damaged.

Preparing the Engine for accessory connection:

Note:

 

The Evo-System Engine has a micro switch 

incorporated within the coupling design that senses 

when an accessory has been successfully attached to the 

machine. The engine will not start without an accessory 

being successfully connected. It cannot be run as a ‘stand 

alone’ machine.

•   Lock the Transportation Wheels using the wheelbrake. 

•  Release the Accessory Mounting Frame by rotating the 

locking levers to their unlocked (down) position and push 

levers in.

•  Deploy the Accessory Mounting Frame. 

•  Lock the frame into position by pulling out and returning 

the locking levers to their locked (upright) position.

Pump connection

Note:

 The Pump is equipped with 3 locating pins and 2 

rear stabilising pins. The 3 locating pins lock into the ‘Uni-

coupling’. The other 2 stabilising pins slide into the sockets  

in the Accessory Mounting Frame.

•  Hold the accessory by its external frame and offer it up to the 

engine.  Visually align the 3 locating pins 

(Fig.1a & Fig.1b)

 

and 2 rear stabilising pins 

(Fig.1c)

.  Enlist competent help  

if necessary.

•  Holding onto a convenient part of the external engine 

frame can aid the operator achieving and maintaining 

alignment when connecting an accessory. 

•  Gently push the accessory into the engine. Keep the 

3 locating pins and the 2 stabilising pins aligned with 

their respective docking positions. The internal coupling 

between the engine and the accessory will be made 

Summary of Contents for DWP1000

Page 1: ...ORIGINAL MANUAL Please read instructions before operating this tool DWP1000 DIRTY WATER PUMP SV SK RU PT PL NO NL IT GB FR FI ES EL DE DA CZ...

Page 2: ...ROWS INDICATE STEP 3 APPLY GENTLE HORIZONTAL PRESSURE WITH AN OPEN HANDED FLAT PALM AS ARROW INDICATES AND LOCK IN DO NOT APPLY SEVERE DIAGONAL DOWN WARD PRESSURE AS ARROW INDICATES DOING SO MAY DAMAG...

Page 3: ...elow Instantly watch the HD Evo System Video on your Smart Phone Make sure the HD setting is on If you don t have a Smart Phone you can also watch all Evolution s videos online QR CODE SEEING IS BELIE...

Page 4: ...s Ltd Venture One Sheffield S20 3FR Declare that the product Evolution DWP1000 Dirty Water Pump Part numbers DWP1000 Complies with the essential requirements of the following European Directives 89 33...

Page 5: ...ond recommended capacities and specifications Electrical components are subject to respective manufacturers warranties All goods returned defective shall be returned prepaid freight to Evolution Power...

Page 6: ...f Dress properly Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Loose clothes jewellery or long hair can be caught in moving parts g If devices are p...

Page 7: ...uel immediately The application of dry sand is an effective way of neutralising fuel spills j Do not allow the engine to run out of fuel Surging of the engine as it uses the last of the fuel could cau...

Page 8: ...the fuel cap The vapour is extremely flammable and may ignite on contact with a hot surface or flames DWP1000 WATER PUMP SPECIFICATION Inlet Outlet Diameter 75mm Pump Lift 28 metres Suction Height 8...

Page 9: ...SV SK RU PT PL NO NL IT GB FR FI ES EL DE DA CZ 1 Evo System Engine 2 DWP1000 Water Pump 3 Inlet Port 4 Outlet Port 5 Filler Plug 6 Drain Plug 2 1 3 4 5 6 Machine Overview General view of Water Pump c...

Page 10: ...com 1 Evo System Engine 2 DWP1000 Water Pump 3 Filler Plug 4 Pump Drain Plug 5 Fuel Tap Switch Choke on off 6 On Off switch 7 Foot brake 6 7 5 2 1 3 4 Machine Overview General view of Water Pump conne...

Page 11: ...ling design that senses when an accessory has been successfully attached to the machine The engine will not start without an accessory being successfully connected It cannot be run as a stand alone ma...

Page 12: ...k in the inlet suction hose could prevent priming and reduce the flow rate of the pump If using fixed steel pipework always ensure that the connection to the pump body is made with a piece of flexible...

Page 13: ...area is well ventilated and that there is no danger from the expelled exhaust gases Note The Evo System Engine is fitted with a low oil level shut down feature which protects the engine from damage du...

Page 14: ...ruction Manual for the Evolution Engine 4 Pump Output Note Output of the pump is determined by the speed of the engine and by the length and elevation of the pipe runs 5 Shutting Down To shut down pum...

Page 15: ...lubricant onto the drive cog If the pump has been used to pump salty or contaminated water of any kind it should be thoroughly flushed with clean water both the inside and the outside as soon as poss...

Page 16: ...Did you know you can also buy with more outputs available SOON PRESSURE WASHER OUTPUT EVO SYSTEM ENGINE GENERATOR OUTPUT WATER PUMP OUTPUT...