Evolution 026-0007 Original Instructions Manual Download Page 13

13

www.evolutionpowertools.com

EN

DE

• Safely store the outer blade flange and associated fixings.
•  Rotate the lower blade guard up into the upper blade guard 

using the manual thumb lever.

 

(Fig. 5) 

•   Carefully remove the blade (if fitted) from the machine. 
•   Thoroughly clean inner and outer blade drive flanges.

Note: The inner blade flange can be left in place if desired, but it 
should be checked and thoroughly cleaned. If it is removed from 
the machine it must be replaced back in the same orientation as 
it was before removal.
 •  Thoroughly clean the blade around the bore area (both 

surfaces) where the blade flanges will touch and clamp  
the blade.  

• Install the (new) blade.
•  Ensure that the direction of rotation arrows printed on the 

blade, match the direction of rotation arrows found on the 
machines upper and lower blade guards. (Fig. 6)

• Reinstall the outer drive flange, the socket headed arbor 

screw, and its associated fixings.

Note: The outer drive flange has a specially machined bore 
which incorporates two opposed ‘flats.’ (Fig. 7) These ‘flats’ 
engage with two complimentary ‘flats’ machined into the 
machines arbor shaft.
•  Re-engage the arbor lock and tighten the arbor socket headed 

screw securely using the Hex Key.

•  Release the arbor lock button.
•  Return the Hex Key to its dedicated storage position.
•  Check that the arbor lock has fully released by manually 

rotating the blade.

•  Check the operation of the lower blade guard.

(11) 

PARALLEL EDGE GUIDE  

A Parallel Edge Guide (Fig. 8)

 

which can be particularly  

helpful when rip cutting, is supplied with all CCS machines. 
The guide can be fitted to the front of the sole plate.
The guides arm should be inserted through the rectangular slots 
positioned at either side (front) of the pressed steel sole plate, 
and slid under the centrally located adjustment locking screw. 

(Fig. 9)

 

 

Note: The Parallel Edge Guide can be fitted on either side of the 
sole plate.

WARNING:  Only fit and adjust the Guide with the machine 
disconnected from the power supply. 

Note: The arm of the Parallel Edge Guide must pass through all 
of the rectangular slots provided in the sole plate. 

Fig. 5

Fig. 6

Fig. 7

Fig. 8

Summary of Contents for 026-0007

Page 1: ...Original written in UK English Date Published 15 08 2018 Original Instructions bersetzung der Originalbetriebsanleitung Model drawings may differ to item supplied GB2438285 026 0007 026 0008 F165...

Page 2: ...nal Safety Instructions for circular saws Page 10 GETTING STARTED Unpacking Page 10 Items Supplied Page 10 Machine Overview Page 11 Preparation Page 12 Installing Removing a blade Page 12 Parallel Edg...

Page 3: ...organization but Technical help is also available from your supplier 1 3 CONTACT Web www evolutionpowertools com Email customer services evolutionpowertools com 1 4 WARRANTY Congratulations on your pu...

Page 4: ...mm Max Cutting Thickness 90 53mm Max Cutting Thickness 45 34mm BLADE SPECIFICATIONS F165 CCSL Blade Diameter 165mm Number of Teeth 14 Bore Diameter 20mm Kerf 1 7mm SPECIFICATIONS NOISE VIBRATION DATA...

Page 5: ...tion level during operation e g the work surfaces condition and orientation and the type and condition of the machine being used Before each use such factors should be assessed and where possible appr...

Page 6: ...t is a Hand Operated Circular Saw and must only be used as such It must not be modified in any way or used to power any other equipment or drive any other accessories other than those mentioned in thi...

Page 7: ...ols to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cor...

Page 8: ...use Many accidents are caused by poorly maintained power tools f Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier t...

Page 9: ...igned saw blade causing an uncontrolled saw to lift up and out of the workpiece toward the operator When the blade is pinched or jammed tightly by the kerf closing down the blade stalls and the motor...

Page 10: ...spect the machine and the blade before each use Do not use deformed cracked worn or otherwise damaged blades c Never use the saw without the original guard protection system Do not lock the moving gua...

Page 11: ...OWER BLADE GUARD 5 PARALLEL EDGE GUIDE 6 ERGONOMIC FRONT HANDLE 7 CARBON BRUSHES 8 ALLEN KEY BLADE CHANGE 9 DEPTH ADJUSTMENT LOCKING LEVER 10 DEPTH SCALE 11 REAR HANDLE INCORPORATING SAFETY START ON O...

Page 12: ...hen changing the machines blade Locate the supplied Blade Change Hex Key which is housed in the onboard storage facility similarly positioned on all machines Fig 1 Place saw on a level secure surface...

Page 13: ...ecially machined bore which incorporates two opposed flats Fig 7 These flats engage with two complimentary flats machined into the machines arbor shaft Re engage the arbor lock and tighten the arbor s...

Page 14: ...11 Using these features can aid rapid setting Note Although the depth scale and index mark are very useful enabling rapid depth setting using them should always be regarded as a guide to the setting a...

Page 15: ...which these machines may be used We recommend that the operator seeks advice from a competent authority or the workshop supervisor if they are at unsure of any aspect of using these machines It is im...

Page 16: ...nt authorities and seek additional guidance if Asbestos contamination is suspected 16 ON OFF TRIGGER SWITCH Note All the CCS family of circular saws are equipped with a safety start trigger switch to...

Page 17: ...e that the operators hand or fingers do not touch any part of the machines blade When a cut has been completed Release the ON OFF Trigger switch Allow the blade to come to a complete stop Remove the m...

Page 18: ...bed in fully 20 GENERAL MAINTENANCE CLEANING Note All maintenance must be carried out with the machine switched off and disconnected from the power supply Check that all safety features and guards are...

Page 19: ...RoHS Directive 2012 19 EU The Waste Electrical and Electronic Equipment WEEE Directive And is in conformity with the applicable requirements of the following documents EN 62841 1 2015 EN62841 2 5 2015...

Page 20: ...k Industrial Estate Sheffield S20 3FR 44 0 114 251 1022 US Evolution Power Tools LLC 8363 Research Drive Davenport Iowa 52806 1 866 EVO TOOL EU Evolution Power Tools SAS 61 Avenue Lafontaine 33560 Car...

Reviews: