22
EvoHeat Fusion-i Series Manual
Three Phase Unit
Nameplate maximum
current
Phase line
Earth line
MCB
Creepage Protector
Signal Line
No more than 10A
2 x 1.5mm
2
1.5mm
2
20A
30mA less than 0.1 sec
n x 0.5mm
2
10~16A
2 x 2.5mm
2
2.5mm
2
32A
16~25A
2 x 4mm
2
4mm
2
40A
25~32A
2 x 6mm
2
6mm
2
40A
32~40A
2 x 10mm
2
10mm
2
63A
40~63A
2 x 16mm
2
16mm
2
80A
63~75A
2 x 25mm
2
25mm
2
100A
75~101A
2 x 25mm
2
25mm
2
125A
101~123A
2 x 35mm
2
35mm
2
160A
123~148A
2 x 50mm
2
50mm
2
225A
148~186A
2 x 70mm
2
70mm
2
250A
186~224A
2 x 95mm
2
95mm
2
280A
If the unit is to be installed outdoors, ensure that a UV resistant cable is used.
8.4 Comparison Table of Refrigerant Saturation Temperature
Pressure
(MPa)
0
0.3
0.5
0.8
1
1.3
1.5
1.8
2
2.3
Temperature
(R410A)(°C)
-51.3
-20
-9
4
11
19
24
31
35
39
Temperature
(R32)(°C)
-52.5
-20
-9
3.5
10
18
23
29.5
33.3
38.7
Pressure
(MPa)
2.5
2.8
3
3.3
3.5
3.8
4
4.5
5
5.5
Temperature
(R410A)(°C)
43
47
51
55
57
61
64
70
74
80
Temperature
(R32)(°C)
42
46.5
49.5
53.5
56
60
62
67.5
72.5
77.4