Evo315-C Manual
Page 5
5. Installation
5.1 System Installation
Upon receiving the unit, check the packaging for any obvious signs of damage. Inform EvoHeat immediately if there is
any evidence of rough handling.
Do not drill any fixings or attachments into the outer
casing of the tank. Drilling into the outer casing of the
tank may damage the heating coil and WILL VOID
WARRANTY.
The P&T valve attached with the unit must be installed.
Failure to do so will cause damage to the unit and
possible personal injury.
Drain the water tank through the drain valve at the
bottom part of the unit.
Do not use stainless steel fittings to connect directly with
other metals to prevent galvanic corrosion.
Note:
A pressure releasing valve is to be fitted within the installation. Spec of P&T valve: Pressure: 0.85MP Temperature: 99°C
Water Inlet or Outlet Pipes:
The specification of
the water inlet and outlet thread is BSP3/4 (internal
thread). Pipes must be heat-resistant and durable.
Piping for the P&T Valve:
The spec of the valve
connecting thread is BSP3/4 (internal thread). After
installation, confirm that the drainpipe outlet is
exposed in the air. When the flexible drainpipe is
joined to the pressure relief orifice of this valve,
ensure that the flexible drainpipe is pointing
downwards and exposed in the air.
5.2 Handing & Transportation
The unit should be stored and/or transported in its shipping container in an upright position and without water charge.
For transport over short distances, and provided due care is exercised, an inclination angle of up to 30 degrees is
permitted. During transport and storage, ambient temperatures of -10 to +60 degrees Celsius are permissible.
Forklift Transportation
Manual Transportation
The unit must remain mounted on the pallet
and lifted at minimal speed. Due to its top
heaviness, the unit must be secured against
tipping over and placed on a level surface.
Ensure that the maximum permissible inclination angle of 60
degrees is not exceeded. If transport in an inclined position
cannot be avoided, the unit should be left to rest at least one hour
after it has been moved into final position before operation.