4. PC Connection
4.1 Things to Know before Connection
Warning
The connected or built-in peripherals with opposite polarities are not allowed.
Warning
The device only operates when connecting with grounded power. No operation is
allowed when the device power is ungrounded or only impedance is grounded.
Warning
Rated voltage of the device in use shall be in accord with power feature of the
product.
Note:
Only the peripheral devices approved for industrial application can be used. When
operating the PC, hot swappable IO modules (USB) can be used. The IO devices
without hot swap function can only be connected when the PC is powered off.
4.2 Product Grounding
Low impedance ground connection is more helpful to release the interference
produced by the external cables, the signal cables or the cables connecting the IO
module to the grounding system.
Ground Terminals
The equipotential bonding terminal
①
on the device shall be connected with
the cabinet installed with the PC or the
central grounding busbar on the device.
The minimum cross section area of the
cable shall be no less than 2.5mm
2
. The
maximum ground resistance should be
no more than 0.1
Ω
.
Summary of Contents for MEC-5071-M Series
Page 1: ...MEC 5071 M SERIES 微型低功耗无风扇嵌入式整机 Micro low power fanless embedded PC Version C00 ...
Page 39: ...软件介绍 MEC 5071 M SERIES 31 3 GPIO ...
Page 48: ...BIOS 功能介绍 40 MEC 5071 M SERIES Advanced Super IO Configuration 该项提供本平台的串口 COM1 4 和并口 ...
Page 58: ...BIOS 功能介绍 50 MEC 5071 M SERIES System Agent SA Configuration 该项提供关于 System Agent 功能的配置 ...
Page 61: ...BIOS 功能介绍 MEC 5071 M SERIES 53 PCH IO Configuration 该项提供 Intel PCH 芯片的功能配置 AC Power Loss ...
Page 63: ...BIOS 功能介绍 MEC 5071 M SERIES 55 HD Audio Configuration 该项提供关于声卡的配置 Security ...
Page 76: ...扩展安装 68 MEC 5071 M SERIES 拆卸SIM卡 拆卸SIM卡的步骤 1 卸下前面板门 2 取出SIM卡 ...
Page 82: ...尺寸图 74 MEC 5071 M SERIES 11 3 产品安装尺寸图 203 180 156 72 65 5 90 33 5 5 4 5 65 65 单位 mm ...
Page 102: ......
Page 126: ...Product Installation 16 MEC 5071 M SERIES Figure 4 Upward ventilation ...
Page 144: ...Software Introduction 34 MEC 5071 M SERIES from system error 3 GPIO ...