93
ENGINE MANAGEMENT MODULE (EMM)
ENGINE MONITORING SYSTEM
5
ENGINE MONITORING
SYSTEM
The engine monitoring system warns the operator
of conditions that could damage the outboard. The
system includes sensors on the engine and oil
tank, a warning horn, a dash-mounted gauge, and
related wiring.
The
EMM
sends information about monitored
functions to:
•
An
I-Command
, or other
NMEA 2000
compliant
CANbus network
•
The
SystemCheck
Modular Wiring System
(MWS)
•
EMM
LED indicators
IMPORTANT:
Outboards with remote controls
must be equipped with an
I-Command
system, a
SystemCheck
gauge, or an equivalent engine
monitor. Operating the outboard without an
engine monitor will void the warranty for failures
related to monitored functions.
The
EMM
activates the warning horn and gauge
displays as follows:
•
LOW OIL means that oil in the tank is at reserve
level (about 1/4 full).
•
NO OIL indicates the oil tank is empty.
•
WATER TEMP or HOT indicates an engine or
EMM
overheat condition.
•
CHECK ENGINE or FAULT is used to indicate
other fault conditions identified by the
EMM
.
Refer to the
EMM
Service Code Chart
at the
back of this manual for a complete list of all fault
codes.
System Self-Test
During engine start-up, pause with the key switch
in the ON
position. The horn self-tests by sound-
ing a half-second beep.
SystemCheck
gauges
self-test by turning the indicator lights on simulta-
neously, then off in sequence.
Service Mode
SystemCheck
goes into a service mode if the key
is left ON after self-test (engine NOT
running). All
light circuits and sensors are active, but the horn
is not. Grounding the appropriate light circuit wire
will turn the light on, but the horn will not sound.
Refer to
Engine Running
All warning circuits are active when the engine is
running. The horn circuit is active when engine
speed exceeds 500 RPM.
Engine monitor warnings activate the horn for 10
seconds and the appropriate gauge light for a
minimum of 30 seconds. If the failure is momen-
tary (for example, oil moving in the tank), the light
will remain ON for the full 30 seconds before
going out. If the fault continues, the light remains
ON until the key is turned OFF or the failure is cor-
rected. The warning will reoccur at the next start-
up if the problem is not corrected.
Typical
I-Command
and
SystemCheck
gauges
006707
Summary of Contents for E75DPLSCB
Page 1: ...2008 SC E TEC 75 90 P N 5007527 75 90 HP 5007527 Service Manual ...
Page 2: ......
Page 231: ...POWERHEAD POWERHEAD VIEWS 229 11 POWERHEAD VIEWS Port Short Block Starboard Short Block ...
Page 232: ...230 POWERHEAD POWERHEAD VIEWS Port Dressed Powerhead Starboard Dressed Powerhead ...
Page 233: ...POWERHEAD POWERHEAD VIEWS 231 11 Front ...
Page 234: ...232 POWERHEAD POWERHEAD VIEWS Rear ...
Page 235: ...POWERHEAD POWERHEAD VIEWS 233 11 Top ...
Page 302: ...S 2 ...
Page 349: ...2008 SC E TEC 75 90 P N 5007527 75 90 HP 5007527 Service Manual ...