background image

 

14 

MAINTAINING THE PNEUMATIC TOOL

 

 

 

When working on air tools, note the warnings in this manual and use extra care 

evaluating problem tools. Disconnect air supply and empty the magazine when 

inspecting or maintaining the tool.

 

REPLACEMENT PARTS: 

 

Use only genuine parts from the manufacturer or distributor. Do  not  use  modified  parts  or   parts  which  will  not  give 
equivalent performance to the original equipment.   
Tighten all screws. 
Keep contact arm moving smoothly. 
 

ASSEMBLY PROCEDURE FOR SEALS: 

 

When  repairing  a  tool,  make  sure  the  internal  parts  are  clean  and  lubricated. Use  O-Ring lubricant on all O-Rings. 
Coat  each  O-Ring  with  O-Ring lubricant  before  assembling.  Use  a  small  amount  of  oil on all moving surfaces and 
pivots.  After reassembly add a few drops of Air Tool Lubricant through the air line fitting before testing. 

 

AIR PRESSURE AND VOLUME: 

 

Air volume is as important as air pressure. The air volume supplied to the tool may be inadequate because of undersize 
fittings  and hoses,  or from the effects of dirt  and  water in the system. Restricted air flow  will  prevent the  tool  from 
receiving an  adequate volume of air, even though the pressure reading  is high. The results  will be  slow  operation, 
misfeeds or reduced driving power.  Before evaluating tool  problems for these symptoms, trace  the  air  supply  from 
the tool to the supply source for restrictive connectors, swivel fittings, low points containing water and anything else 
that would prevent full volume flow of air to the tool. 

 

DRIVER MAINTENANCE INSTRUCTIONS

 

 

Worn driver causing poor quality or loss of power:   

Wear or a chip on the driving tip will affect the nail drive, giving symptoms of bent and incompletely driven nails, and

 

damaged nail heads. 

The driver length may be adjusted to allow the driving tip to be redressed to compensate for wear. Heat and precise 
measurement are required. Contact a qualified service technician for this adjustment. 

The length setting for a new driver is shown below. Measurement is from the bottom face of the main piston. 

Note that the measurement from the top of the piston gives the maximum amount the driver may be adjusted to allow 
redressing.  Always extend the driver the minimum required to allow

 

redressing to restore the driving end; several re-

dressings will be possible before this maximum depth is reached. 

When using optional flangeless driver, see adjustment below. Be sure to use proper preparation and installation.  

 

 

 

 

 

 

TROUBLESHOOTING / REPAIRS

 

 

The troubleshooting and / or repairs shall be carried out only by the authorized dealer / distributor 

or 

by other 

pneumatic tool specialists.

 

 

Standard  Length

 

5.429”  –  5.453”  (137.9  –  138.5  mm)

 

Summary of Contents for SCN65

Page 1: ...MANUAL CE DECLARATION OF CONFORMITY 19 3 19 Everwin Pneumatic Corp BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE ...

Page 2: ...dditional safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin Pneumatic Corp Taichung City Taiwan 41353 INDEX 1 Year Limited Warranty 3 CE Declaration of Conformity 4 Safety Instructions 5 Specifications 6 Technical Data 6 Operating Pressure Setting Correct P...

Page 3: ...seals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenance operation not within the operation manual s specification etc are not covered by this warranty c Labor charges loss repairs from improper maintenance and or usage of non EVERWIN parts are not cover...

Page 4: ...IC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserklæring CE Deklaration DANSK EVERWIN PNEUMATIC CORP erklærer herved at produktet er i overenstemmelse med nedenstående normer eller normative dokumenter 2006 42 EC i henhold til bestemmelserne i EU s direktiv EN 792 13 Öve...

Page 5: ...sed the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 Whe...

Page 6: ... 19 P T male plug The inside diameter should be 280 7 mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air supply OPERATING PRESSURE 70 to 120 PSI 5 to 8 kg cm2 Select the operating pressure within this range for best fastener performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE TECHNICAL DATA AIR CONSUMPTION Tool air consumption 2 3 cfm...

Page 7: ...GGER CONTINUOUS BUMP FIRE OPERATION WITH SMART TRIGGER The common operating procedure on Contact Trip tools is for the operator to contact the work to actuate the trip mechanism while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject t...

Page 8: ... the air system The supply hose should contain a fitting that will provide quick disconnecting from the male plug on the tool SUPPLY SOURCE Use only clean regulated compressed air as a power source for this tool NEVER USE OXYGEN COMBUSTIBLE GASES OR BOTTLED GASES AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE REGULATOR A pressure regulator with an operating pressure of 0 125 PSI 0 8 79 kg cm ...

Page 9: ...ure no malfunction on the tool due to ice formation Some commercial air line drying liquids are harmful to O Rings and seals do not use these low temperature air dryers without checking compatibility NAIL LOADING EYE PROTECTION which conforms to ANSI CE specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in t...

Page 10: ...hers in the work area when connecting to air supply loading operating or servicing this tool Eye protection is required to guard against flying fasteners and debris which could cause severe eye injury The employer and or user must ensure that proper eye protection is worn Eye protection equipment must conform to the requirements of the ANSI Z87 1 and 89 686 EEC and provide both frontal and side pr...

Page 11: ...e trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated finger still holding trigger p...

Page 12: ...mechanism Push and rotate the Trigger Lock Dial to the trigger free position before driving nails DIRECTIONAL EXHAUST COVER ALWAYS disconnect air supply before rotating the exhaust cover by hand Direction of the exhaust air is changed by rotating exhaust cover by hand ...

Page 13: ... trigger press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION Use this pneumatic tool only for the purpose for which it was designed like pallet crating sheathing decking applications Never use this tool in a manner that could cause a fastener to be directed toward th...

Page 14: ...uced driving power Before evaluating tool problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that would prevent full volume flow of air to the tool DRIVER MAINTENANCE INSTRUCTIONS Worn driver causing poor quality or loss of power Wear or a chip on the driving tip will affect th...

Reviews: