8.2. SERVICING
INSTRUCTIONS
CAUTION – These servicing instructions are for use by qualified service
personnel only. To reduce the risk of electric shock do not perform any
servicing instructions in this section of the manual unless you are qualified
to do so.
8.2.1. Changing the Fuses
Check that the line fuse is rated for the correct value marked on the rear
panel. Never replace with a fuse of a greater value.
The fuse holder is located inside the power entry module. To change the fuses, remove the fuse holder
from the power entry module using a small screwdriver. The fuse holder contains two fuses, one for the
line and one for the neutral side of the mains connection. Remove the blown fuse and replace it with a
fuse of the correct value. Replacement fuse type: T1AL250V, slow blow, 1A, 250VAC (non LNB),
T4AL250V, slow blow, 4A, 250VAC (LNB option).