HD9010TM High Definition Time Code Master Manual
OPERATION
Revision 2.4.1
Page 3-3
When not in the
VCG Window Select Mode
, press this key and turn the
SHAFT ENCODER
knob to position all the character windows vertically on the screen. (See also section 3.6.4.)
VSIZE
When in the
VCG Window Select Mode
the VSIZE key is used to select whether the
selected window will be displayed in normal vertical size or double vertical size. When not
in the
VCG Window Select Mode,
this key has no function. On Older units this button is
labelled
INFO.
The Double Height character function is only available with firmware version 2.0 build
285 and later.
3.1.5. The Function Button Group
ANC GEN
Is used to turn the RP188 ancillary generator on and off. The ANC GEN indicator is ON
when the RP188 generator is enabled. The time and user bits of the RP188 generator are
the same as for the primary LTC generator.
JAM
Is used to momentarily jam the primary reader’s time into the generator time. When the
SHIFT + JAM keys are pressed the HD9010TM generator will be put into continuous jam
sync mode. (See section 3.5.1 for information about selecting the primary reader).
HOLD
When the generator time (
GTM
) is displayed on the front panel, pressing the
HOLD
key stops
the generator time from incrementing. A special character (
H
) appears to the left of the
numeric display on the front panel, indicating that the display is in Hold mode. Pressing the
HOLD
key again starts the generator incrementing.
When one of the readers is displayed on the front panel, pressing the
HOLD
key freezes the
reader display data on the front panel and in the VCG. A special character (
F
) appears to
the left of the numeric display on the front panel, indicating that the display is in Freeze
mode. Press the
HOLD
key again to return to normal update mode.
3.1.6. The Preset Button Group
SAVE
Is used to save the current configuration of the HD9010 into one of the user preset
memories. The Front panel prompts you to enter the preset number you want to load
Save Preset #?
Use the numbered keys to select the preset memory to save into. The front panel shows the
preset memory to save to, and the current video standard.
Sv 3 AUTO-I/60 ?
To select another preset memory press one of the numbered keys. To confirm saving the
preset press the
SELECT
key. The front panel shows:
Sv 3<AUTO-I/60