OPERATION
3.2.
FRONT PANEL DISPLAY FUNCTIONS
3.2.1. Front Panel Displays
The
DISPLAY
key is used to select which data is being displayed in the alphanumeric display. Each
time the
DISPLAY
key is pressed, the front panel display cycles to the next available display. The
leftmost characters of the display indicate what is being displayed as follows:
GTM 12:34:56:00
Generator Time information
GUB 12 34 56 78
Generator User Bit information
LTM 12:34:56:00
LTC Reader Time information
LUB 12 34 56 78
LTC Reader User Bit information
VTM 12:34:56:00
VITC Reader Time information
VUB 12 34 56 78
VITC Reader User Bit information
When the reader time or user bits are being displayed the active reader will be indicated by an asterisk
(e.g.
LTM*
indicates that the LTC reader is active, or
VTC*
indicates that the VITC reader is active) See
section 3.5.1 for more information on selecting which reader is active.
There are also some extended displays which are accessible by pressing the
SHIFT + DISPLAY
keys.
Press
SHIFT + DISPLAY
to return to the normal displays. At this time the extended displays are:
OFFS 00:00:00:00
Jam Sync Offset register
REVT 00:00:00:00
Time at which Reader Time Event GPO will occur
GEVT 00:00:00:00
Time at which Generator Time Event GPO will occur
JAM@ 00:00:00:00
Reader Time at which a momentarily jam will occur
Details on setting the REVT and GEVT registers can be found in section 3.7.9.5. Details on setting the
JAM@ register can be found in section 3.4.4.1.
3.2.2. Special Front Panel Indicators
The following special indicators are used between the seconds and frames digits of the front panel time
display to identify non-drop frame and drop frame code (NTSC only).
Non Drop Frame
Colon (:)
Drop Frame (NTSC)
Period (.)
The following special indicators are used between the hours and minutes digits of the front panel time
display when the 8010TM is in Time/Date mode generating local time and the time being adjusted for
Daylight Saving Time.
DST Time Off
Colon (:)
DST Time On
Period (.)
Summary of Contents for 8010TM
Page 2: ...This page left intentionally blank ...
Page 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Page 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...