7800 MultiFrame Manual
7800FC VistaLINK
®
Frame Controller
Page-14
Revision 1.0
2.
Install the 7800FC card into the frame. After the card powers up and the boot-up messages are
finished, a “login” prompt will appear in the terminal window. (For future reference 7800FC
software version information is displayed prior to the “login” prompt and should be quoted to Service
staff when required.)
For example:
Kernel Build Date : Jan 28, 2013
Software : v1.2 Build 2
Tag : 7801FC_r1-2-2
Software Build Date : Jan 30, 2013
Wed Jan 30 11:05:46 GMT 2013
NetBSD/evbppc (780xfc) (console)
login:
3.
If the prompt does not appear, the following is a list of possible reasons for failed communications:
•
Defective Serial Upgrade cable.
•
Wrong communications port selected in the terminal program.
•
Improper port settings in the terminal program. (Refer to step 1 for settings).
4.
At the “login” prompt, enter:
•
“
customer
” for user name <Enter>
•
“
customer
” for password <Enter>
NOTE - Neither username nor password can be modified at the time of this manual
revision release.
5.
A menu for Network, SNMP and FC Upgrade Setup Configuration appears and is detailed in the
next section.
6.2. CONFIGURING THE NETWORK SETTINGS
From main menu, three selections are available -
Network Setup
,
SNMP Setup
.
•
Network Setup
is used to set network IP addresses as well as broadcasting and routing instructions
•
SNMP Setup
is used to identify up to ten trap destination IP addresses.
**** Main Menu ****
<1> Network Setup
<2> SNMP Setup
<X> Exit
<W> Exit without saving to flash
>