7700 MultiFrame Manual
7707VB-8-ASI-OC3 8 Channel ASI + Ethernet SONET / SDH Fiber Transceiver
Revision
1.0
Page - 15
4.2.1.8.
Displaying the Link Input Status
This menu selection displays the
Link Input Status
. To display the
Link Input Status
from the
STAT
menu,
use the toggle switch/pushbutton to select the
FIBR
menu item and then choose the
REF
menu item,
followed by
INP
.
STAT
FIBR
REF
INP
LOS
FOS
OK
The following indications are possible:
LOS
Link Lost
FOS
Frequency Offset
OK
Link Valid
4.2.1.9.
Displaying Input ASI Status Information
This menu selection displays various information contained in the input DVB-ASI stream. Parameters
such as
Total TS Bit Rate
,
Null Packet Bit Rate
,
Useful Bit Rate
,
Number of Active PID’s
, and
Number of
Continuity Count Errors
can be displayed. To display the
ASI Status Information
from the
STAT
menu, use
the toggle switch/pushbutton to select the
IASI
menu and then choose one of
RATE, NULL, DATA
,
PID
,
or
CCER
under
ASI(1-8).
STAT
IASI
ASI1- ASI8
RATE, NULL,
DATA, PID, CCER
0-107 for rates
0-128 for PID’s
0-9999 for error
counter
The following indications are possible:
RATE
Total TS Bit Rate
NULL
Null Packet Bit Rate
DATA
Useful Bit Rate
PID
Number of Active PID’s
CCER
Number of Continuity Count Errors
4.2.1.10.
Displaying the Total Input ASI Bandwidth Used
This menu selection displays the sum of the 8 input channel bandwidths. To display the
Total Input
Bandwidth
used from the
STAT
menu, use the toggle switch/pushbutton to select the
IASI
menu and then
choose
IPBW
,
followed by
USED
.
STAT
IASI
IPBW
USED
The following indications are possible:
USED
Combined Input Bandwidth