7700 MultiFrame Manual
7707VB-8-ASI-OC3 8 Channel ASI + Ethernet SONET / SDH Fiber Transceiver
Revision
1.0
Page - 13
The following menu is available to display performance counts:
STAT
FIBR
CIC
15m
24h
ESL
SESL
ESS
SESS
ESP
SESP
SEFS
ESL
Errored Seconds Line – Seconds having detected B2
errors.
SESL
Severe Errored Seconds Line (threshold set by
CTRL/NET/SETH/SESL).
ESS
Errored Seconds Section – Seconds having detected B1
errors.
SESS
Severe Errored Seconds Section (threshold set by
CTRL/NET/SETH/SESS).
ESP
Errored Seconds Path – Seconds having detected B3
errors.
SESP
Severe Errored Seconds Path (threshold set by
CTRL/NET/SETH/SESP).
SEFS
Severe Errored Frame Seconds – Seconds having severe
errored frames.
4.2.1.4.
Displaying the Last Interval Counter
This menu displays
Last Interval Performance Counts
recorded each time the
Live Interval
counters
expire. To display these performance counts from the
STAT
menu, use the toggle switch/pushbutton to
select the
FIBR
menu item and then choose the
LAST
menu item. The module records
Last
interval
counts for 15 minute and 24 hour intervals. The corresponding status is displayed by selecting either the
15m
or
24h
menu item. The following selections are available to display performance counts:
STAT
FIBR
LAST
15m
24h
ESL
SESL
ESS
SESS
ESP
SESP
SEFS
ESL
Errored Seconds Line – Seconds having detected B2
errors.
SESL
Severe Errored Seconds Line (threshold set by
CTRL/NET/SETH/SESL).
ESS
Errored Seconds Section – Seconds having detected B1
errors.
SESS
Severe Errored Seconds Section (threshold set by
CTRL/NET/SETH/SESS).
ESP
Errored Seconds Path – Seconds having detected B3
errors.
SESP
Severe Errored Seconds Path (threshold set by
CTRL/NET/SETH/SESP).
SEFS
Severe Errored Frame Seconds – Seconds having severe
errored frames.