6. JUMPERS
LOCAL FAULT
EVERTZ (A) 7707BPX
SFF POWER
+12V
GND
ON
Dot Matrix
Display
SERIAL
J8
FRAME STATUS
OFF
J3
RE
M/CTL
J7
UP
G
R
A
D
E
/RUN
J4
1
234
GPI1
LO
GPI2
HI
J16
J15
CH A PWR
CH B PWR
CH A ACTIVE
CH B ACTIVE
Figure 6-1: Location of Jumpers – Main Module
6.1.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
The FRAME STATUS jumper J3 located near the back rear of the module determines whether local faults
(as shown by the Local Fault indicator) will be connected to the 7700FR frame's global status bus.
FRAME STATUS:
To monitor faults on this module with the frame status indicators (on the Power
Supply FRAME STATUS LED's and on the Frame's Fault Tally output) install this
jumper in the On position. (Default)
When this jumper is installed in the Off position local faults on this module will not
be monitored.
6.2.
SELECTING WHETHER MODULE WILL BE CONTROLLED FROM THE
LOCAL CONTROLS OR THROUGH THE VISTALINK
®
INTERFACE
The REM/CTL jumper J7 selects whether the module will be controlled from the local user controls or
through the
Vista
LINK
®
interface.
REM/CTL:
When this jumper is installed in the CTL position, the card functions are controlled
through the local controls.
When this jumper is installed in the REM position, the card functions are controlled
through the
Vista
LINK
®
interface.