7700 MultiFrame Manual
7707BPX Optical Bypass
Protection
Switch
Page-8
Revision
1.6
3. SPECIFICATIONS
3.1. OPTICAL
INPUT/OUTPUT
Number:
3 Bi-directional optical signals
Connector:
Female SC/PC, ST/PC or FC/PC
Insertion Loss:
< 3 dB
Switch Time:
< 30 msec
Maximum Input Power:
0
dBm
Input Optical Sensitivity
: -40 dBm
Wavelengths:
1270nm to 1610nm
Fiber Size:
9
µ
m core / 125
µ
m overall
3.2.
GENERAL PURPOSE INPUTS
Number of Inputs:
2
Type:
Opto-isolated, active low with internal pull-ups to +5V
Connector:
2 pins plus ground on 6 pin terminal strip
Signal Level:
+5V Pullup:
Low: -5 to +2.5 VDC, High: 3.5 to 10 VDC
+12V Pullup:
Low: -5 to +9.5 VDC, High: 10.5 to 15 VDC
Max Sink Current:
(input shorted to ground) 15 mA
Max Leakage Current for input High:
200
µA
3.3.
GENERAL PURPOSE OUTPUTS
Number of Outputs:
1
Type:
“Dry Contact” relay contacts - normally open and normally closed contact provided
Connector:
3 pins on 6 pin terminal strip
3.4. ELECTRICAL
Voltage:
+12VDC
Power:
3
Watts
EMI/RFI:
Complies with FCC regulations for class A devices
Complies with EU EMC directive
3.5. PHYSICAL
7700 or 7701 frame mounting:
Number of slots:
1