570NAT-HW-X19
High Density Network Address Translator
Page - 16
Revision
1.0
4.1.5. Global Traffic Monitoring
Total WAN Ports Rx Bandwidth (Mbps):
This parameter displays the total received bandwidth for all
WAN Ethernet ports.
Total WAN Ports Tx Bandwidth (Mbps):
This parameter displays the total sent bandwidth for WAN
Ethernet ports.
Total LAN Ports Rx Bandwidth (Mbps):
This parameter displays the total received bandwidth for all
LAN Ethernet ports.
Total LAN Ports Tx Bandwidth (Mbps):
This parameter displays the total sent bandwidth for LAN
Ethernet ports.
4.1.6. Temperature Monitoring
FPGA Temperature:
This monitor will display the temperature of the FPGA.
4.1.7. TTL
TTL:
This field allows the user to enter the Time To Live (TTL) to be used on each separate core of the
NAT.
4.1.8. Global Data Port SFP Alarm Threshold
Use sliders to set alarm thresholds for Rx, Tx, Voltage and Temperature conditions of SFPs.
It is recommended users consult with the documentation for their SFPs and use their operational
specifications as a guideline for setting the SFP alarms.
SFP Rx Power High Alarm Threshold (dBm):
Alarm will trigger if SFP Rx exceeds this threshold.
SFP Tx Power Low Alarm Threshold (dBm):
Alarm will trigger if SFP Rx falls below this threshold.
SFP Rx Power High Alarm Threshold (dBm):
Alarm will trigger if SFP Tx exceeds this threshold.
SFP Tx Power Low Alarm Threshold (dBm):
Alarm will trigger if SFP Tx falls below this threshold.
SFP Voltage High Alarm Threshold (V):
Alarm will trigger if SFP voltage exceeds this threshold.
SFP Voltage Low Alarm Threshold (V):
Alarm will trigger if SFP voltage falls below this threshold.
SFP Temperature High Alarm Threshold (
°
C):
Alarm will trigger if SFP temperature exceeds this
threshold.
4.1.9. System
System Reboot:
This button allows the user to reboot the 570NAT-HW-X19 module, doing this will result
in the connection being lost temporarily while the unit resets. A warning pop-up may appear in
WebEASY
®
during this time, wait for the unit to reset.
Factory Reset:
This button will reset the 570NAT-HW-X19 unit to factory default settings and firmware.