570ASI–X19-10GE2 Series
User Manual
Page - 20
Fail Over Mode Selection:
This dropdown allows the user to select the failover mode for the received
master PCR stream.
•
Automatic
•
Main
•
Backup
Fail Over Status:
This parameter displays the current status of the master PCR fail over.
PTP or Master PCR Presence:
This parameter indicates whether a valid Master PCR is present or a
valid PTP stream is present.
Locked:
This parameter indicates whether the card is locked to Master PCR or PTP.
4.5.2. PTP Control
For SFPP 1 to 6
Domain Number:
This control allows the user to set the domain number.
4.5.3. Master PCR Control
IP Address:
This field allows the user to set the IP address from which to obtain the Master PCR time
reference.
UDP Port Number:
This field allows the user to set the UDP port number from which to obtain the
Master PCR time reference.
PCR PID:
This parameter allows the user to set the expected PCR PID.
PCR Presence:
This field indicates whether PCR presence is detected on this data port or not.
IGMPv3 Mode:
This field allows the user to select the Master PCR IGMP V3 mode.
IGMPv3 SSM Src 1-6:
This parameter allows the user to set Master PCR IP addresses which are used
when forming the source filter for IGMPv3 communications.
Summary of Contents for 570ASI-X19-10GE2
Page 2: ...This page left intentionally blank ...
Page 6: ...570ASI X19 10GE2 Series User Manual Page ii This page left intentionally blank ...
Page 10: ...570ASI X19 10GE2 Series User Manual Page vi This page left intentionally blank ...
Page 12: ...570ASI X19 10GE2 Series User Manual Page 2 This page left intentionally blank ...
Page 19: ...570ASI X19 10GE2 Series User Manual Page 9 4 1 SYSTEM Figure 4 4 WebEASY System Part 1 of 2 ...
Page 26: ...570ASI X19 10GE2 Series User Manual Page 16 Figure 4 9 WebEASY IP Input Control Part 2 of 2 ...