EMR User's Guide
High Density Modular Audio Router (AES, Analog, MADI, TimeCode, Data)
Page 148
Revision 1.8
APPENDIX A
9.6.
EMX-FC UPGRADE
•
Connect the Ethernet cable to either A or B port of the frame and make sure the card is pingable.
•
FTP to the card, there is no user name and password
•
Change the directory to “app” , “ftp:>cd\boot\app”.
•
Type “hash” at the prompt, then type “put” + space and then drag and drop the firmware
•
Type “bye” once the transfer is completed and reboot the card is manually. (The card will not
reboot automatically.)
9.7.
MAGNUM SERVER CONFIGURATION
•
Add an EMR frame under the Devices and leave the default IP address and Port number.
•
Edit the EMR frame and then add the ADMX/EMR-ADMX-48 X48.
•
For the Primary IP address enter the A Network IP address of the Left EMX-FC.
•
For the Port use Port 4001.
Note: In this example port 4000 is used because during EMX-FC configuration
“0” was entered for port index. Port indexes “0-14” corresponds to Ports
“4000-4014” respectively.
•
For the Secondary IP address enter the A Network IP address of the Right EMX-FC.
•
For the Port use Port 4000.