2432RX2-HDMI
Dual Path Serial Digital to HDMI Converter
UPGRADING FIRMWARE
Revision 1.0
Page - 43
5.2. FTP UPGRADE METHOD
1. Set the IP address on the unit.
2. Connect serial port to the unit.
3. Open HyperTerminal and set the serial setting as follows:
Baud
115200
Parity
no
Data bits
8
Stop bits
2
Flow Control
None
Table
5-2 : Serial Terminal Settings
4. Press “Enter” to access the menu.
5. Select Option 1. Network Configuration
6. Select Option 1. Set IP address and enter the IP address. Once complete press the <enter> key.
7. Select Option 2. Set Netmask and enter the Netmask. Once complete press the <enter> key.
8. Press “S” to save and exit.
9. Reboot the unit.
10. Open a command prompt on the computer where 2432RX2-HDMI network cable is plugged.
11. Ping the 2432RX2-HDMI to confirm it is reachable from the computer.
12. Ftp to the unit. Press enter for user name and password.
13. Type “quote site upgrade” in the command prompt and press the <enter> key.
14. Type “Put_”, then drag and drop the “runtime” file. Once complete press the <enter> key
(_ represent space after the Put command)
15. After the ftp is complete, the card will reboot automatically.