EVERSPRING AN157 Manual Download Page 1

AN157 

 ON/OFF MODULE 

 

This AN157 plug-in ON/OFF Module is a transceiver which is a Z-Wave

TM

 enabled 

device and is fully compatible with any Z-Wave

TM

 enabled network. Z-Wave

TM

 

enabled devices displaying the Z-Wave

TM

 logo can also be used with it regardless 

of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave

TM

 

enabled networks. Remote On/Off control of the connected load is possible with 
other manufacturer’s Wireless Controller. Each module is designed to act as a 
repeater.  Repeaters will re-transmit the RF signal to ensure that the signal is 
received by its intended destination by routing the signal around obstacles and 
radio dead spots. The AN157 plug-in ON/OFF Module is compatible with our 
Motion Detectors SP103 and Door/Window Detectors SM103. 
 

Include to or Exclude from a Z-Wave

TM

 Network 

 
In the front casing, there is an On/Off button with LED indicator which is used to 
carry out inclusion, exclusion, reset or association.    Toggle On/Off button between 
On and Off.  When first power is applied, its LED flashes on and off alternately 
and repeatedly at 2-second intervals.    It implies that is has not been assigned a 
node ID and cannot work with Z-Wave enabled devices.    Please get familiar with 
the terms below before starting the operations. 

 

Function

 

Description

 

Inclusion 

 

Add a Z-Wave enabled device (e.g. On/Off Module) to Z-Wave network.

 

Exclusion 

 

Delete a Z-Wave enabled device (e.g. On/Off Module) from the network.

 

Association 

 

After inclusion, you have to define the relationship between devices. Trough 
association, device can be assigned as master/slave, and specify which 
slave is going to be controlled by which master.

 

Reset

 

Restore On/Off Module to factory default.

 

 
 
 
 
 
 
 
 
 
 

 
 

Installation 
 

1.  Plug this On/Off Module into a wall outlet near the load to be controlled. 
 
2.  Plug the load into the Module.  Make sure the load to be controlled cannot 

exceed 2990/3500 watts. 

 
3.  Press the button or switch on the load to the ON position. 
 
4.  To manually turn ON the Module, press and release the On/Off button. The 

LED will turn ON, and the load plugged into the Module will also turn ON. 

 
5.  To manually turn OFF the Module, simply press and release the On/Off button. 

The LED will turn OFF and the load plugged into the Module will also turn OFF. 

 
6.  If Motion Detector SP103 or Door/Window Detector SM103 has been removed 

from the wall by triggering the tamper switch, the Detector (SP103 or SM103) 
will send an alarm command 

(ALARM_REPORT, Alarm Type == 0x01, Alarm 

Level == 0x11) 

to the Module, of which LED and the load plugged into the 

Module will be on and off intermittently for 10 seconds. 

 

Note:

 When putting Motion Detector or Door/Window Detector in use, do not 

connect the load belongs to motor or electronic transformers, as the load 
would be impaired. 

 

Programming 

 

The On/Off button allows the user 

Turn on or off the load attached 

Include or exclude the Module from the Z-Wave

TM

 system 

Control other Z-Wave

TM 

enabled devices 

 
See the instructions for SP103 Motion Detector or SM103 Door/Window Detector. 
   

Troubleshooting 

                                   

Symptom 

Cause of Failure 

Recommendation 

The Module not working and 
LED off 

1.  The Module is not 

plugged into the 
electrical outlet 
properly 

2.  The Module is out of 

order 

1.  Check power connections 
2. Don’t open up the Module and 

send it for repair. 

On/Off Button 
LED Indicator 