EVH 100
Plus
With Everhot Cookers’ policy of continuous product improvement, the manufacturer reserves the right to c
hange specifications and make
modifications to the appliance described and illustrated at any time
s:/installation specs/EVH 100 Plus installation spec.doc/ver30415
INSTALLATION INSTRUCTIONS & SPECIFICATION
PRE
–
INSTALLATION
NOTE:
The preparation of the site, in readiness for the installation of the appliance, is the responsibility
of the site owner, not of the manufacturer of the appliance.
a.
The floor must be level and capable of supporting the weight of the cooker (approximate weight
350kg).
b.
The cooker measurements are 600mm deep and 900mm high to the working surface with a width
of 995mm . The EVH 100 Plus should be installed with a minimum of 15mm clearance from the
back wall.
This 15mm gap is best sealed with a worktop upstand, though a standard 30mm
stainless infill strip that fits to the back of the cooker can be bought from Everhot.
On no account
should any Everhot model be pushed hard against the back wall as this may damage the electric
cable. A minimum gap of 5mm per side is required to allow installation and removal of the cooker
–
please contact us in advance of installation if this is not possible. Where the end grain of a
wooden worktop is adjacent to the cooker, we recommend that this is increased to 10mm to
minimise the chance of the worktop splitting.
c.
Clearance must be allowed for the raising of the cooker lid into the upright position (minimum height
of 1530mm from ground level). Please see side view diagrams for further clarification. A 5mm gap
on each side of the cooker lid should be allowed when in the raised position (the lids are slightly
inset from the side of the cooker to allow for overhead cupboards).
d.
The appliance must be used on 220-240V AC only and should be plugged into a standard 13 amp
socket. The 13 amp socket should be accessible and positioned adjacent to the cooker, so as not
to impede the opening of the top lid, and ensuring the plug is not exposed to steam or excessive
moisture. If the socket cannot be positioned immediately adjacent to the cooker, please see
diagrams attached for exact lengths of cables (unfortunately it is not possible to extend these cable
lengths). If the power supply cord is damaged, it must be replaced by the manufacturer or their
representative, as special purpose tools are required.
An Everhot cooker should NOT be hard
wired
–
please install using the supplied 13amp plug
.
POST INSTALLATION
Point a. below will normally be checked by the
EVERHOT
technician who installs your cooker
a. Before use, check that the cooker is level, upright and stable.
b. On reaching working temperature, ensure that the hot/simmer plate surfaces are flush with the
surrounds - this can be adjusted using a 5mm allen key in the bolts at each corner of the hotplates.
c
.
On initial heating up odours may be given off from the insulants used. These will disappear after a
number of hours.
Your
EVERHOT
cooker has been built to comply with the following European Directives, and carries the CE mark.
1. EMC Directive (2004/108/EC) 2. Low Voltage Directive (2006/95/EC)
Control of Substances - Health and Safety
This appliance contains the following substances indicated below. It is the User’s/Installer’s responsibility to ensure that
the
appropriate precautions are taken when handling, where applicable, any of the materials that could be interpreted as being
injurious to health and safety.
Mineral wool, Glass Yarn.
May cause irritation to the skin, eyes, nose and throat, may be harmful if inhaled. Use appropriate protective clothing to avoid
contact with body. After handling, wash hands and other exposed parts.
Your cooker does not contain ceramic insulants
The EVERHOT is a high quality appliance that will provide decades of use, however when you feel that it has reached the end
of its working life, please contact us and we will remove it and recycle it free of charge