background image

 

                                  

                         eIVP-CFS-IV-V0004

 

 

56 

4.5.1

 

HDD Security Configuration 

 

Figure 4-5-1: HDD Security Settings

 

Set User Password 

Set HDD user password. 

*** Advisable to power cycle system after setting hard disk passwords *** 

Discard or save changes option in setup does not have any impact on HDD when password is 

set or removed. If the 'Set HDD User Password' option is gray, do power cycle to enable the 

option again. 

 

4.5.2

 

Security Boot 

 

Figure 4-5-2: Security Boot Settings 

Attempt Secure Boot 

Secure Boot activated when Platform Key (PK) is enrolled, System mode is User/Deployed, and 

CSM function is disabled. 

Secure Boot Mode 

Secure Boot mode selector Standard/Custom. 

In custom mode Secure Boot Variables can be configured without authentication. 

Summary of Contents for eIVP-CFS-IV-V0004

Page 1: ...eIVP CFS IV V0004 AI Mobile NVR Intel Core i7 i5 with 4 PoE Ports User s Manual Copyright EverFocus Electronics Corp Release Date August 2020...

Page 2: ...hout notice Copyright All rights reserved No part of the contents of this manual may be reproduced or transmitted in any form or by any means without written permission of the EverFocus Electronics Co...

Page 3: ...liquid or spray detergents Make sure the device is installed near a power outlet and is easily accessible Keep this device away from humidity Place the device on a solid surface during installation to...

Page 4: ...the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local...

Page 5: ...Cable 8 2 5 Installing CFast Card 10 2 6 Installing SIM Card 11 2 7 Installing SSD HDD 12 2 8 Installing M 2 14 2 9 Mounting Your eIVP CFS IV V0004 15 2 9 1 Wall mount 16 2 9 2 VESA mount 16 2 9 3 Din...

Page 6: ...d 39 4 3 1 CPU Configuration 40 4 3 2 Power Performance 41 4 3 2 1 CPU Power Management Control 41 4 3 2 2 GT Power Management Control 42 4 3 3 PCH FW Configuration 42 4 3 4 Trusted Computing 43 4 3 5...

Page 7: ...5 Security 55 4 5 1 HDD Security Configuration 56 4 5 2 Security Boot 56 4 6 Boot 57 4 7 Save Exit 58 5 Appendix 59 5 1 Function Description 59 5 2 Isolated DIO Signal Circuit 60 5 3 RAID Functions 61...

Page 8: ...e vibration of eIVP CFS IV V0004 s SSD is certificated with IEC 60068 2 64 while the shock is certificated with IEC 60068 2 27 It supports onboard GPS and GLONASS Besides the model is also CE FCC EN50...

Page 9: ...2 Contact the shipper if any items appear to have been damaged in the shipping process 3 The DVD contains the User Manual and some Drivers for the system If you can t find the required drivers from th...

Page 10: ...more details please refer to 1 4 3 WLAN LED Mini PCIe SIM Card Comparison 5 PWR HDD LED Indicator HDD LED Yellow A Hard Disk CFast LED If the LED is on it indicates that the system s storage is funct...

Page 11: ...ke sure the system is powered off Unlock the SSD Tray using the supplied SSD Lock Key 1 4 1 Power Button The Power Button is a non latched switch with dual color LED indication It indicates power stat...

Page 12: ...o Description Pin No Description S1 GND PC6 NC S2 SATA_TXP5 PC7 GND S3 SATA_TXN5 PC8 CFAST_LED S4 GND PC9 NC S5 SATA_RXN5 PC10 NC S6 SATA_RXP5 PC11 NC S7 GND PC12 NC PC1 GND PC13 3 3V PC2 GND PC14 3 3...

Page 13: ...a computer or to any other devices with Ethernet connection such as hubs and switches Moreover both of LAN 1 and LAN 2 support Wake on LAN and Pre boot functions The pin outs of LAN 1 and LAN 2 are li...

Page 14: ...lable supporting up to 5Gb per second data rate It is also compliant with the requirements of Super Speed SS high speed HS full speed FS and low speed LS 4 Isolated DIO There is a 16 bit 8 bit DI 8 bi...

Page 15: ...is supported by standard RJ 45 connector with LED indicators to present Active Link Speed status of the connection The LED indicator on the right bottom corner lightens in solid green when the cable i...

Page 16: ...auto flow control The pin assignments are listed in the following table Serial Port Pin No RS 322 RS 422 5 wire RS 422 9 wire RS 485 3 wire 1 to 4 1 DCD TXD TXD DATA 2 RXD TXD TXD DATA 3 TXD RXD RXD 4...

Page 17: ...er UL 1577 CSA Component Acceptance Notice 5A IEC 60950 1 and IEC 61010 1 End Equipment Standards GB4943 1 2011 CQC Certified DIO Connectors pin out DIO Pin No Definition Function DIO 1 INPUT 0 SIO_GP...

Page 18: ...eIVP CFS IV V0004 2 DI reference circuit DO reference circuit Sink Mode NPN Default Source PNP Sink Mode NPN Source Mode PNP...

Page 19: ...stallation 2 1 How to Open Your eIVP CFS IV V0004 Step 1 Turn eIVP CFS IV V0004 bottom side up and remove 6pcs HEX 6 32 crews from the front panel Step 2 Remove front panel Step 3 Turn over eIVP CFS I...

Page 20: ...4 Step 4 Remove 5pcs HEX 6 32 screws circled in red from the rear side and 4pcs PHILLIPS 6 32 screws circled in yellow from the bottom side Step 5 Remove rear panel Step 6 Remove the SATA cable and S...

Page 21: ...eIVP CFS IV V0004 5 Step 7 Finished 2 2 Installing DDR4 SO DIMM Modules Step 1 DDR4 SO DIMM socket...

Page 22: ...eIVP CFS IV V0004 6 Step 2 Install DDR4 RAM module into SO DIMM socket Step 3 Install DDR4 RAM module into SO DIMM socket...

Page 23: ...eIVP CFS IV V0004 7 2 3 Installing Mini PCIe Card Step 1 Mini PCIe socket Step 2 Install Mini PCIe card into socket...

Page 24: ...eIVP CFS IV V0004 8 Step 3 Install Mini PCIe card into socket 2 4 Installing Antenna Cable Step 1 Check antenna cable and washer Step 2 Rear panel antenna hole...

Page 25: ...eIVP CFS IV V0004 9 Step 3 Install antenna cable Step 4 Fasten washer 1 and 2...

Page 26: ...CFS IV V0004 10 Step 5 Finished 2 5 Installing CFast Card Step 1 Remove 2pcs PHILLIPS M3 screws on CFast SIM cover at front panel Step 2 Before installing CFast make sure the system power is not work...

Page 27: ...004 11 Step 3 Insert CFast card and push to lock 2 6 Installing SIM Card Step 1 Remove 2pcs PHILLIPS M3 screws on CFast SIM cover at front panel Step 2 Before install CFast make sure the system power...

Page 28: ...eIVP CFS IV V0004 12 Step 3 Insert SIM card and push to lock 2 7 Installing SSD HDD Step 1 Unlock SSD HDD tray...

Page 29: ...eIVP CFS IV V0004 13 Step 2 Pull the trigger and open SSD HDD tray Step 3 Install 2 5 SSD HDD into the tray and then push back to close the tray...

Page 30: ...eIVP CFS IV V0004 14 Step 4 Lock the SSD HDD tray with the SSD HDD tray key 2 8 Installing M 2 Step 1 M 2 socket...

Page 31: ...cs PHILLIPS M3 screw 2 9 Mounting Your eIVP CFS IV V0004 EverFocus provides wall mount brackets in the package If you need other brackets for VESA mount Din Rail Kit and 2U rack mount kit as described...

Page 32: ...eIVP CFS IV V0004 16 2 9 1 Wall mount Fasten 6pcs PHILLIPS 10 32 screws 2 9 2 VESA mount Fasten 6pcs PHILLIPS 10 32 screws VESA 75 x 75 100 x 100 mm...

Page 33: ...eIVP CFS IV V0004 17 2 9 3 Din Rail Kit Fasten 6pcs PHILLIPS 10 32 screws 2 9 4 2U rack mount kit...

Page 34: ...eIVP CFS IV V0004 18 3 Jumpers and Connectors on the Motherboard 3 1 Main Board Expansion Connectors 3 1 1 Top View Component Side of eIVP CFS IV V0004 Main Board With Connector Location Chapter 3...

Page 35: ...der can be used as a backup for following functions such as hard drive LED indicator reset button power LED indicator and power on off button which already can be accessed by front panel and top panel...

Page 36: ...age capacity with less cabling effort and smaller required space The pin assignments of SATA1 and SATA2 are listed in the following table Pin No Definition Pin No Definition 1 GND 5 RXN 2 TXP 6 RXP 3...

Page 37: ...80Mbps It is also compliant with the requirements of high speed HS full speed FS and low speed LS The pin assignments of CN13 are listed in the following table Pin No Definition Pin No Definition 1 5V...

Page 38: ...FS IV V0004 22 Slot Description SODIMM_1 DDR4 Channel A SODIMM_2 DDR4 Channel B 3 1 8 CN1 BIOS Socket If the BIOS needs to be changed please contact the EverFocus Technical Support team ts everfocus c...

Page 39: ...Out Pin No Function Pin No Function 1 5V_AUX 2 12V 3 3 3V 4 SMB_DATA 5 3 3V 6 XMB_CLK 7 Reserved 8 Reserved 9 Reserved 10 SPI_MISO 11 USB_OC 12 SPI_MOSI 13 Reserved 14 SPI_CLK 15 5V 16 SPI_CS10 17 USB...

Page 40: ...PET_N0 44 A_PER_N0 45 GND 46 APRSNT A_PE_C LKREQ 47 PERST 48 A_CLKP 49 WAKE 50 A_CLKN 51 5V 52 GND SUMIT B Pin Out Pin No Function Pin No Function 1 GND 2 GND 3 B_PET_P0 4 B_PER_P0 5 B_PET_N0 6 B_PER_...

Page 41: ...C_PET_P3 34 C_PER_P3 35 C_PET_N3 36 C_PER_N3 37 GND 38 GND 39 PERST 40 WAKE 41 Reserved 42 Reserved 43 5V 44 Reserved 45 5V 46 3 3V 47 5V 48 3 3V 49 5V 50 3 3V 51 5V 52 5V_AUX 3 1 10 Mini PCIe MPCIe_1...

Page 42: ...ND 37 GND 38 USB_D 35 GND 36 USB_D 33 PETp0 34 GND 31 PETn0 32 SMB_DATA 29 GND 30 SMB_CLK 27 GND 28 1 5V 25 PETp0 26 GND 23 PETn0 24 3 3 Vaux 21 GND 22 PERST 19 Reserved 20 Reserved 17 Reserved 18 GND...

Page 43: ...ace the lithium battery on your own If the battery needs to be changed please contact the EverFocus Technical Support team ts everfocus com tw zk 3 1 12 FN1 FAN Header Fan power connector supports for...

Page 44: ...Q 7 LFRAME 2 3 3V 8 LAD0 3 LA3 9 N C 4 RESET 10 Ground 5 LAD1 11 CLOCK 6 LAD2 12 Ground 3 1 14 J4 J5 LAN3 LAN4 LAN5 LAN6 Speed LED Header J4 Pin Out Pin LAN PORT Function 1 LAN3 LINK100 2 LAN4 LINK100...

Page 45: ...3 3V 75 GND 72 3 3V 73 RESERVED REFCLKn1 70 NC 71 RESERVED REFCLKp1 68 NC 69 GND 66 NC 67 RESERVED PETn1 64 NC 65 RESERVED PETp1 62 ALERT O 0 3 3V 63 GND 60 12C_CLK I 0 3 3V 61 RESERVED PERn1 58 12C_D...

Page 46: ...9 NC 6 LED1 O od 7 GND 4 3 3V 5 USB_D 2 3 3V 3 USB_D 1 GND 3 1 16 M 2 KEY M PCIe x4 SATA Support M 2 key M connector is suitable for applications that use Host I Fs supported by either PCIe or SATA or...

Page 47: ...T I O O 0 3 3V or N C 51 GND 48 NC 49 PETp0 SATA A 46 NC 47 PETn0 SATA A 44 NC 45 GND 42 NC 43 PERp0 SATA B 40 NC 41 PERp0 SATA B 38 DEVSLP O 39 GND 36 NC 37 PETp1 34 NC 35 PETn1 32 NC 33 GND 30 NC 31...

Page 48: ...A jumper is a metal bridge used to close an electric circuit It consists of two metal pins and a small metal clip often protected by a plastic cover that slides over the pins to connect them To close...

Page 49: ...rt RI pin Select Pin Header Pin No Description COM1 JP2 1 2 5V 1A max 3 4 12V 0 5A max 5 6 RI Default Pin Header Pin No Description COM1 JP4 1 2 5V 1A max 3 4 12V 0 5A max 5 6 RI Default Pin Header Pi...

Page 50: ...PoE power on after system power on Default JP7 No Jumper Disable PoE power 3 2 5 JCMOS1 JP1 CMOS ME Flash Jumper Setting Function JCMOS1 1 2 Normal Default JCMOS1 2 3 Clear CMOS Jumper Setting Functi...

Page 51: ...pre defined on off delay periods 3 3 1 Adjust Ignition Control Modes eIVP CFS IV V0004 provide 16 modes of different power on off delay periods adjustable via SW5 switch The default dip switch is set...

Page 52: ...ds 6 hours D 10 seconds 8 hours E 10 seconds 12 hours F 10 seconds 24 hours 3 3 2 Ignition Control Wiring To activate ignition control you need to provide IGN signal via the 3 pin pluggable terminal b...

Page 53: ...IV V0004 supports 6V to 36V wide range DC power input in ATX AT mode In Ignition mode the input voltage is fixed to 12V 24V for car battery scenario 3 For proper ignition control the power button sett...

Page 54: ...1 Entering BIOS Setup Figure 4 1 Entering Setup Screen BIOS provides an interface for users to check and change system configuration The BIOS setup program is accessed by pressing the Del key when POS...

Page 55: ...e two options on Main menu System Date Set the date Use Tab to switch between date elements System Time Set the time Use Tab to switch between time elements 4 3 Advanced Figure 4 3 BIOS Advanced Menu...

Page 56: ...nology Active Processor Cores Number of cores to enable in each processor package Hyper threading Enabled for Windows XP and Linux OS optimized for Hyper ThreadingTechnology and disabled for other OS...

Page 57: ...efore OS handoff Intel R SpeedStep tm Allows more than two frequency ranges to be supported Intel R Speed shift Technology Enable Disable Intel Speed Shift Technology support Enabling will expose the...

Page 58: ...ed to min max supported by SKU Disable Turbo GT frequency Check to enable render standby support 4 3 3 PCH FW Configuration Figure 4 3 3 PCH FW Settings ME State Set ME to Soft temporarily disabled AM...

Page 59: ...s Enable Hibernation Enables or disables system s ability to hibernate OS S4 sleep state This option may not be effective with some OS ACPI Sleep State Selects the highest ACPI sleep state the system...

Page 60: ...to Serial Port 4 Entering the corresponding Port option then end user can change the settings such as I O resource and UART mode High Speed Serial Port is Port 1 only 4 3 8 Hardware Monitor Figure 4 3...

Page 61: ...9 Serial Port Console Redirection Figure 4 3 9 Serial Port Console Redirection Settings Console Redirection Console redirection enable or disable Console Redirection Settings These settings specify h...

Page 62: ...mation Display Intel TXT information 4 3 11 Acoustic Management Configuration Figure 4 3 11 Acoustic Management Settings Acoustic Management Configuration Option to enable or disable automatic acousti...

Page 63: ...on set to Enabled it provides a Setup screen for selecting PCI resource padding for Hot Plug 4 3 13 Network Stack Configuration Figure 4 3 13 Network Stack Settings Network Stack Enable Disable UEFI N...

Page 64: ...llow GA20 to be disabled this option is useful when any RT code is executed above 1MB Option ROM Messages Set display mode for Option ROM INT19 Trap Response BIOS reaction on INT19 trapping by Option...

Page 65: ...ontroller and Drive information 4 3 16 USB Configuration Figure 4 3 16 USB Settings Legacy USB Support Enables Legacy USB support AUTO option disables Legacy support if no USB devices are connected DI...

Page 66: ...r up delay Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a root port it is 100 ms for a hub port the delay is taken from the hu...

Page 67: ...Figure 4 4 1 1 Memory Information Displays memory information 4 4 1 2 Graphics Configuration Figure 4 4 1 2 Graphics Settings Skip Scaning of External Gfx Card If Enable it will not scan for External...

Page 68: ...please disable CSM Support DVMT Pre Allocated Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphics Device DVMT Total Gfx Mem Select DVMT5 0 Total Graphic Memory size...

Page 69: ...r failure G3 state S0 State Always turn on the system when power source plugged in S5 State Always turn off the system when power source plugged in 4 4 2 1 PCI Express Configuration of PCH IO Figure 4...

Page 70: ...refer to the SWFM configuration to enable or disable the storage features Aggressive LPM Support Enable PCH to aggressively enter link power state Options for each SATA port Port n Enable or disable S...

Page 71: ...4 2 3 Security Settings BIOS Lock Enable disable the PCH BIOS Lock Enable BLE bit feature 4 5 Security Figure 4 5 BIOS Security Menu Administrator Password Set administrator password User Password Set...

Page 72: ...pact on HDD when password is set or removed If the Set HDD User Password option is gray do power cycle to enable the option again 4 5 2 Security Boot Figure 4 5 2 Security Boot Settings Attempt Secure...

Page 73: ...r of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Boot Option...

Page 74: ...ing the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to...

Page 75: ...ange in out direction in runtime process DIO definition is shown below Pin No DIO Definition GPIO Definition Pin No DIO Definition GPIO Definition 1 DI 0 DIO 0 11 DO 0 DIO 8 2 DI 1 DIO 1 12 DO 1 DIO 9...

Page 76: ...rt No Definition 1 POE 0 3 POE 2 2 POE 1 4 POE 3 Do NOT use these functions in below 1 PE 2000 DIO1 ID 0 POE 2 PE 3000 POE ID 0 3 UE 1000 USB ID 0 5 2 Isolated DIO Signal Circuit DI reference circuit...

Page 77: ...OS menu Advanced SATA Configuration SATA Mode Selection RAID Intel RST Premium 5 3 2 UEFI Mode for RAID 1 Please select SATA device to RAID mode on BIOS menu Advanced SATA Configuration SATA Mode Sele...

Page 78: ...Disabled Save Changes and Reset 4 Into BIOS menu again select Intel R Rapid Storage Technology on BIOS menu 5 Select Create RAID Volume on BIOS menu 6 Select disks to create RAID Volume then Save Cha...

Page 79: ...EverFocus product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at their end of l...

Reviews: