12
If further changes are needed, user can select desired
charging slot (“Slot” button) and change mode/current
anytime by holding “Mode” followed by “Current” button.
Please note that the recommended charging current
should be set to a minimum of 1/4 value in relation to
inserted battery’s rated capacity. For example for the
2000mAh R6/AA batteries the recommended charging
current is 500mA (0.50A) or higher. For the 800mAh
R03/AAA batteries the recommended charging current is
200mA (0.20A) or higher. The default charging current of
500 mA will be suitable for most of the R6 AA/R03 AAA
batteries.
Full charge termination method -∆V is much less reliable
with lower than recommended charging currents.
7.
Operation modes.
Charge mode
– inserted batteries will be charged
automatically with the (pre)selected charging current.
Each battery slot is individually controlled. The default
charging current is 0.50A. In charge mode available values
are: 0.25A/0.50A/0.75A and 1A for each battery slot. After
the charging is complete the LCD will show the charge
capacity (this is not the same as cell’s rated capacity),
operation time, voltage, and END indication.
Discharge mode –
can be used to reduce and minimize
Summary of Contents for NC 1000M