94
will be the same as DSP B’s input 4, etc. The routing configuration still applies.
This is the
same as setting all the
OUTx Wet/Dry
parameters on the
[dsp A]
and
[dsp B]
menu pages in the
LEVELS
area to
0%,
except that the output levels cannot be changed.
If ADAT, AES11-17 etc are connected to external inputs, they will not be affected.
mute
Mutes all the main outputs. If ADAT, AES11-17 etc are connected to
external inputs, they will not be affected.
Put the H8000FW into
system
bypass mode either by placing the cursor over the
system
field and pressing
SELECT
or
by pressing the
BYPASS
key. Once the H8000FW is in
system
bypass mode, the Bypass Status LEDs blink, and the
bypass A
and
bypass B
fields are no longer available.
To get the H8000FW out of
system
bypass mode, either place the cursor over the
system
field and press
SELECT
or
press the
BYPASS
key.
→
See
Remote Controlling the Bypass Functions
on page 112.
Machine Bypass
The two options that exist for
machine
bypass are:
dsp bypass
Makes each output of the bypassed DSP the same as its
corresponding input. The routing configuration still applies.
This is the same as setting all the
OUTx
Wet/Dry
parameters on the
[dsp x]
menu page in the
LEVELS
area to
0%,
except that the output levels cannot be
changed.
mute
Mutes the outputs of the bypassed DSP. The routing configuration still
applies.
Put the H8000FW into
machine
bypass mode
by
SELECT
ing either the
bypass A
field or the
bypass B
field. The corresponding Bypass
Status LED will light when a DSP is bypassed.
To "un"-bypass a DSP, press its
bypass x
field
again. Its corresponding Bypass Status
LED will grow dark . . .
→
See
Remote Controlling the Bypass Functions
on page 112.