__________________________________________________________________________________________________________________
Series GA201-M2
7
LT126 June 2021
SPECIFICATIONS
Equipment Dimensions
Figure 1: GA201-M2
Gas and Power Specifications
Maximum Fire Rate:
46,000 BTH/h
Gas Manifold Pressure
9.8” WC
Ignitor Electric Supply
One (1) “AA” Battery
Maximum Inlet Gas Supply Pressure:
250 psi
Weight without Propane Tank
140 lbs
Propane-Gas Cylinder Compatibility
To be used ONLY with 20lb Propane-Gas Cylinders with a maximum capacity of 8kg (20lb) which meet the criteria
described in the Installation Codes section of this manual.
The Cylinder and its connector fittings must be maintained in good condition.
High Altitude Installation
When installing this heater over 4500 ft. above sea level in Canada, the heater must be properly de-rated and installed
according to local codes. In the absence of local codes, the heater must be de-rated in accordance with the most
recent CSA -B149 code. In the United States for installations over 2000ft above sea level the heater must be installed
in accordance with the Current National Fuel Gas Code, ANSI Z223.1/NFPA 54(the heater shall be de-rated 4 percent
for each 1000 ft of elevation above sea level). High altitude conversion kits are available, contact manufacturer for
more details.