EVCO S.p.A.
c-pro 3
| Hardware manual ver. 2.0 | Code 114CP3E204
page 1 of 86
PROGRAMMABLE CONTROLLERS
ENGLISH
HARDWARE MANUAL ver. 2.0
CODE 114CP3E204
Page 1: ...EVCO S p A c pro 3 Hardware manual ver 2 0 Code 114CP3E204 page 1 of 86 c pro 3 PROGRAMMABLE CONTROLLERS ENGLISH HARDWARE MANUAL ver 2 0 CODE 114CP3E204 ...
Page 2: ... information for the installation and for the electrical connection keep this document close to the devices for future consultations The following symbols support the reading of the document it indicates a suggestion it indicates an additional information to be followed The devices must be disposed according to the local legislation about the collection for electrical and electronic equipment ...
Page 3: ... 31 4 3 1 Meaning of the connectors of c pro 3 EXP hecto and of c pro 3 EXP hecto 31 4 3 2 Example of electrical connection of c pro 3 EXP hecto 36 4 4 Additional information for electrical connection 37 5 USER INTERFACE 38 5 1 Keyboard 38 5 2 Signalling LEDs 38 5 2 1 LEDs at the front of the device 38 5 2 2 LEDs on the RS 485 ports 39 6 CONFIGURATION 40 6 1 Configuring a programmable controller 4...
Page 4: ...able models 70 7 4 3 Size 71 8 ACCESSORIES 72 8 1 Programming kit EVIF20TUXI 72 8 1 1 Introduction 72 8 1 2 Description 72 8 1 3 Size 73 8 1 4 Connection to the Personal Computer 73 8 2 Programming key EVKEY10 73 8 2 1 Introduction 73 8 2 2 Description 73 8 2 3 Size 74 8 2 4 Connection to the controller 74 9 TECHNICAL DATA 75 9 1 Technical data 75 ...
Page 5: ...s keyboard made of silicone rubber integrated in the controller hereinafter also called built in versions blind can be used for example with an user interface such as Vgraph Vtouch or Vroom hereinafter also called blind versions The controllers have got real time clock alarm buzzer not available in the blind versions 4 analog inputs of which 3 configurable via configuration parameter for PTC NTC P...
Page 6: ...gurable via configuration parameter for 0 20 mA 4 20 mA 0 10 V signal 6 digital outputs electromechanical relays of which five 5 res A 250 VAC SPST outputs and one 8 res A 250 VAC SPDT output 2 non optoisolated communication ports of which 1 CAN port with CANbus communication protocol and 1 port to update the firmware of the instrument c pro 3 EXP hecto is available in blind version and can be use...
Page 7: ...85 port with Modbus master slave communication protocol 2 micro switch to plug in the termination of the RS 485 port polarize the network of the RS 485 port plug in the termination of the CAN port 3 CAN port 4 digital outputs 5 display and keyboard available in c pro 3 hecto only not available in the blind versions 6 analog outputs in c pro 3 hecto analog inputs and analog outputs in c pro 3 hecto...
Page 8: ...inafter also called first RS 485 port 2 RS 485 port with Modbus master slave communication protocol hereinafter also called second RS 485 port 3 micro switch to plug in the terminations of the RS 485 ports polarize the network of the second RS 485 port plug in the termination of the CAN port 4 CAN port 5 digital outputs 6 display and keyboard not available in the blind versions 7 analog outputs 8 ...
Page 9: ...called first RS 485 port 2 RS 485 port with Modbus master slave communication protocol hereinafter also called second RS 485 port 3 micro switch to plug in the terminations of the RS 485 ports polarize the network of the second RS 485 port plug in the termination of the CAN port 4 CAN port 5 digital outputs 6 display and keyboard not available in the blind versions 7 slot for gateway c pro 3 plug ...
Page 10: ... of c pro 3 EXP hecto The following table shows the meaning of the parts of the expansion Part Meaning 1 micro switch to plug in the termination of the CAN port 2 CAN port 3 digital outputs 4 analog outputs in c pro 3 EXP hecto analog inputs and analog outputs in c pro 3 EXP hecto 5 analog inputs 6 port to update the firmware of the expansion 7 power supply 8 digital inputs 9 signalling LEDs ...
Page 11: ...re manual ver 2 0 Code 114CP3E204 page 11 of 86 3 SIZE AND INSTALLATION 3 1 Size c pro 3 hecto c pro 3 hecto c pro 3 EXP hecto and c pro 3 EXP hecto 4 DIN modules size in mm in 3 2 Size c pro 3 mega 10 DIN modules size in mm in ...
Page 12: ...EVCO S p A c pro 3 Hardware manual ver 2 0 Code 114CP3E204 page 12 of 86 3 3 Size c pro 3 NODE mega 14 DIN modules size in mm in ...
Page 13: ...press the DIN rail clips to the end first 3 5 Additional information for installation working conditions working temperature humidity etc must be between the limits indicated in the technical data do not install the devices close to heating sources heaters hot air ducts etc equipments provided with big magnetos big speakers etc locations subject to direct sunlight rain humidity dust mechanical vib...
Page 14: ...o 3 hecto and of c pro 3 hecto The following tables show the meaning of the connectors MODBUS RS 485 port with Modbus master slave communication protocol configurable via application software The following drawing shows the aspect of the RS 485 port The following table shows the meaning of the pins of the RS 485 port Pin Meaning 1 common 2 not connected 3 not connected 4 D0 B terminal 0 of the tra...
Page 15: ... controller Function code Meaning FC 01 read coils FC 02 read discrete inputs FC 03 read multiple registers FC 04 read input registers FC 05 write single coil FC 06 write single register FC 08 diagnostic FC 15 write multiple coils FC 16 write multiple registers FC 23 read write multiple registers For the settings about the RS 485 port look at chapter 6 CONFIGURATION MICRO SWITCH Micro switch to pl...
Page 16: ...ad the bus load depends on the baud rate of the CANbus communication and on the kind of device in the network For example a CAN network can be made of a programmable controller of four I O expansions and of four user interfaces with baud rate 500 000 baud The maximum length of the connecting cables of the CAN port depends on the baud rate of the CANbus communication as follows 1 000 m 3 280 ft wit...
Page 17: ...l output 6 NC6 normally closed contact digital output 6 The maximum length of the connecting cables of the digitalhecto ʖ cuts is 100 m 328 ft The maximum current allowed on the loads is 10 A DIGITAL OUTPUTS In c pro 3 hecto Digital outputs 1 2 3 4 and 5 electromechanical relays Terminal Meaning CO1 2 common digital outputs 1 and 2 NO1 normally open contact digital output 1 NO2 normally open conta...
Page 18: ... parameter for 0 20 mA 4 20 mA 0 10 V signal The maximum length of the connecting cables of the PWM analog output is 1 m 3 280 ft the one of the connecting cables of the 0 20 mA 4 20 mA 0 10 V analog outputs is instead of 30 m 98 ft For the settings about the analog outputs look at chapter 6 CONFIGURATION The analog output 1 is usable on condition that the controller is powered in alternate curren...
Page 19: ... inputs DI1 digital input 1 DI2 digital input 2 DI3 digital input 3 DI4 digital input 4 DI5 digital input 5 The maximum length of the connecting cables of the digital inputs is 100 m 328 ft ANALOG INPUTS Analog inputs Each analog input is configurable via configuration parameter for PTC NTC Pt 1000 probes 0 20 mA 4 20 mA 0 5 V ratiometric 0 10 V transducers Terminal Meaning AI1 analog input 1 AI2 ...
Page 20: ...V power supply controller 24 VAC 20 40 VDC V power supply controller 24 VAC 20 40 VDC The maximum length of the connecting cables of the power supply of the controller is 30 m 98 ft Protect the power supply with a fuse rated 0 8A T 250 V If the controller is powered in direct current one will not have to respect the polarity of the power supply voltage ...
Page 21: ...al connection of c pro 3 hecto The following shows an example of electrical connection of c pro 3 hecto To reduce the reflections on the signal transmitted through the cables connecting the devices each other plug in the termination of the CAN port of the first and of the last element of the network ...
Page 22: ...ors of c pro 3 mega and of c pro 3 NODE mega The following tables show the meaning of the connectors MODBUS1 RS 485 port with Modbus slave communication protocol The following drawing shows the aspect of the RS 485 port The following table shows the meaning of the pins of the RS 485 port Pin Meaning 1 common 2 not connected 3 not connected 4 D0 B terminal 0 of the transceiver 5 D1 A terminale 1 of...
Page 23: ...Function code Meaning FC 01 read coils FC 02 read discrete inputs FC 03 read multiple registers FC 04 read input registers FC 05 write single coil FC 06 write single register FC 08 diagnostic FC 15 write multiple coils FC 16 write multiple registers FC 23 read write multiple registers For the settings about the RS 485 port look at chapter 6 CONFIGURATION MODBUS2 RS 485 port with Modbus master slav...
Page 24: ...n guides manual the document is available on the internet site www modbus org Connect the RS 485 port using a twisted pair The following table shows the function codes supported by the controller Function code Meaning FC 01 read coils FC 02 read discrete inputs FC 03 read multiple registers FC 04 read input registers FC 05 write single coil FC 06 write single register FC 08 diagnostic FC 15 write ...
Page 25: ...ition micro switch 4 on position ON to plug in the termination of the CAN port plug in the termination of the first and of the last element of the network CAN BUS CAN port Terminal Meaning CAN signal CAN signal GND ground The maximum number of devices that can make a CAN network 32 depends on the bus load the bus load depends on the baud rate of the CANbus communication and on the kind of device i...
Page 26: ...GITAL OUTPUTS Digital outputs 1 2 and 3 electromechanical relays Terminal Meaning CO1 2 common digital outputs 1 and 2 NO1 normally open contact digital output 1 NO2 normally open contact digital output 2 CO3 common digital output 3 NO3 normally open contact digital output 3 Digital outputs 4 5 6 e 7 electromechanical relays Terminal Meaning CO4 5 common digital outputs 4 and 5 NO4 normally open c...
Page 27: ...t 2 configurable via configuration parameter for 0 20 mA 4 20 mA 0 10 V signal AO3 analog output 3 configurable via configuration parameter for 0 20 mA 4 20 mA 0 10 V signal The maximum length of the connecting cables of the PWM analog output is 1 m 3 280 ft the one of the connecting cables of the 0 20 mA 4 20 mA 0 10 V analog outputs is instead of 30 m 98 ft For the settings about the analog outp...
Page 28: ...log input 2 AI3 analog input 3 AI4 analog input 4 AI5 analog input 5 GND ground 5V power supply 0 5 V ratiometric transducers 5 VDC 40 mA max 24V power supply 0 20 mA 4 20 mA 0 10 V transducers 24 VDC 120 mA max The maximum length of the connecting cables of the analog inputs and the one of the power supply of the transducers is 100 m 328 ft The controller incorporates a restorable thermal protect...
Page 29: ...86 The maximum length of the connecting cables of the power supply of the controller is 30 m 98 ft Protect the power supply with a fuse rated 2 5A T 250 V If the controller is powered in direct current one will not have to respect the polarity of the power supply voltage ...
Page 30: ...connection of c pro 3 mega The following drawing shows an example of electrical connection of c pro 3 mega To reduce the reflections on the signal transmitted through the cables connecting the devices each other plug in the termination of the CAN port of the first and of the last element of the network ...
Page 31: ... termination of the CAN port 120 Ω 0 5 W position micro switch 2 on position ON to plug in the termination of the CAN port plug in the termination of the first and of the last element of the network CAN BUS CAN port Terminal Meaning CAN signal CAN signal GND ground The maximum number of devices that can make a CAN network 32 depends on the bus load the bus load depends on the baud rate of the CANb...
Page 32: ...XP hecto Digital outputs 1 2 3 4 and 5 electromechanical relays Terminal Meaning CO1 2 common digital outputs 1 and 2 NO1 normally open contact digital output 1 NO2 normally open contact digital output 2 CO3 common digital output 3 NO3 normally open contact digital output 3 CO4 5 common digital outputs 4 and 5 NO4 normally open contact digital output 4 NO5 normally open contact digital output 5 Di...
Page 33: ...put 4 NO5 normally open contact digital output 5 Digital output 6 electromechanical relay Terminal Meaning CO6 common digital output 6 NO6 normally open contact digital output 6 NC6 normally closed contact digital output 6 The maximum length of the connecting cables of the digital outputs is 100 m 328 ft ANALOG OUTPUTS in c pro 3 EXP hecto only Analog outputs Terminal Meaning VDC power supply driv...
Page 34: ... for 0 20 mA 4 20 mA 0 10 V signal AO3 analog output 3 configurable via configuration parameter for 0 20 mA 4 20 mA 0 10 V signal The maximum length of the connecting cables of the PWM analog output is 1 m 3 280 ft the one of the connecting cables of the 0 20 mA 4 20 mA 0 10 V analog outputs is instead of 30 m 98 ft For the settings about the analog outputs look at chapter 6 CONFIGURATION The anal...
Page 35: ...g inputs and the one of the power supply of the transducers is 100 m 328 ft The expansion incorporates a restorable thermal protection of the power supplies against the short circuit and the overload For the settings about the analog inputs look at chapter 6 CONFIGURATION PROG Port to update the firmware of the instrument POWER SUPPLY Power supply Terminal Meaning V power supply expansion 24 VAC 2...
Page 36: ...ction of c pro 3 EXP hecto The following drawing shows an example of electrical connection of c pro 3 EXP hecto To reduce the reflections on the signal transmitted through the cables connecting the devices each other plug in the termination of the CAN port of the first and of the last element of the network ...
Page 37: ...ity could condense on the inside wait about an hour before powering it test the working power supply voltage working electrical frequency and working electrical power of the controller they must correspond with the local power supply connect the device to the other devices using a twisted pair disconnect the local power supply before servicing the device do not use the device as safety device for ...
Page 38: ...ED run if it is lit the application software will be compiled and running in release modality if it flashes slowly the application software will be compiled and running in debug modality condition not allowed in c pro 3 EXP hecto and in in c pro 3 EXP hecto if it flashes quickly the application software will be compiled running in debug modality and stopped in a breakpoint condition not allowed in...
Page 39: ...c pro 3 hecto in c pro 3 EXP hecto and in c pro 3 EXP hecto The operation of this LED can be programmed through the development environment UNI PRO 3 5 2 2 LEDs on the RS 485 ports The following drawing shows the aspect of a RS 485 port The following table shows the meaning of the LEDs on the RS 485 ports LED Meaning red LED LED error if it is lit an internal error will have arisen if it flashes q...
Page 40: ...d submenu and to the Parameter Key submenu operate as follows 5 From step 2 press and release button UP or button DOWN to select the submenu 6 Press and release button ENTER 7 Press and release button ENTER again to set the password value 8 Press and release button DOWN over and over again to set 19 9 Press and release button ENTER again To modify a parameter operate as follows 10 From step 9 pres...
Page 41: ...n usually takes a few seconds if an error had to arise the LED system alarm look at paragraph 5 2 1 LEDs at the fron of the device will light up and parameter Key Par it belongs to the Diagnostic submenu will assume value Err 30 Disconnect the programming key To copy the parameters from the programming key EVKEY10 to the controller operate as follows 31 Make sure the power supply is switched on 32...
Page 42: ...Mega LCD Info English Parameters Parameter Key Diagnostic Debug 5 Press and release button UP or button DOWN to select Networks 6 Press and release button ENTER 7 Press and release button ENTER again to set the password value 8 Press and release button DOWN over and over again to set 19 9 Press and release button ENTER again 10 Press and release button UP or button DOWN to select CAN Bus 11 Press ...
Page 43: ...o 3 Mega LCD Info English Parameters Parameter Key Diagnostic Debug 5 Press and release button UP or button DOWN to select Networks 6 Press and release button ENTER 7 Press and release button ENTER again to set the password value 8 Press and release button DOWN over and over again to set 19 9 Press and release button ENTER again 10 Press and release button UP or button DOWN to select CAN Bus 11 Pr...
Page 44: ...ress and release button ENTER 8 Press and release button ENTER again to set the password value 9 Press and release button DOWN over and over again to set 19 10 Press and release button ENTER again 11 Set parameter NW Node using button UP or button DOWN to select the parameter and using button ENTER to modify and to confirm the value According to the factory setting the address of the CAN node of a...
Page 45: ...ormation about UNI PRO 3 version and revision Info SN parameter available in read only modality information about the serial number and the result of the productive test Info MASK parameter available in read only modality information baout the mask it depends on the builder s coding system Info date and time parameter available in read only modality date and time of the last compilation of the app...
Page 46: ...20 mA 4 20mA 4 20 mA 0 10V 0 10 V Parameters 1 AO3 0 10V kind of signal analog input 3 0 20mA 0 20 mA 4 20mA 4 20 mA 0 10V 0 10 V Parameters 1 CosPhi 10us reserved Parameters 2 press button RIGHT to show it I O Timeout 1 240 s 60 time out of the CANbus communication for the test of the remote values of the I O after this time without CANbus communication the I O of the controller is disabled Param...
Page 47: ... 76 800 baud 115K2 115 200 baud Networks CAN Bus MyNode 1 127 1 local or of the controller CAN node address Networks CAN Bus Master YES enabling the operation as master in a CAN network YES yes Networks CAN Bus Baud 20K CANbus communication baud rate 20K 20 000 baud 50K 50 000 baud 125K 125 000 baud 500K 500 000 baud Networks CAN Bus Timeout 1 60 s 5 remote or with a device in the network CANbus c...
Page 48: ... in a RS 485 network wired on the RS 485 port Networks UART1 1 Baud Rate 9600 Modbus communication baud rate in a RS 485 network wired on the RS 485 port 1200 1 200 baud 2400 2 400 baud 4800 4 800 baud 9600 9 600 baud 19200 19 200 baud 28800 28 000 baud 38400 38 400 baud 57600 57 600 baud Networks UART1 1 Parity EVEN Modbus communication parity in a RS 485 network wired on the RS 485 port NONE no ...
Page 49: ... level 1 one has to set a password 32768 32767 0 value of the password to gain access to level 2 Password Level 2 ON enabling the password to gain access to level 2 OFF to gain access to level 2 one has not to set any password ON to gain access to level 2 one has to set a password 32768 32767 0 value of the password to gain access to level 3 Password Level 3 ON enabling the password to gain access...
Page 50: ...atus ok not in error err in error Diagnostic RTC parameter available in read only modality clock status ok not in error err in error low loss of data Diagnostic STACK parameter available in read only modality stack status ok not in error err in error because of overflow Diagnostic Power Supply parameter available in read only modality power supply voltage status ok not in error err in error becaus...
Page 51: ...nds rx parameter available in read only modality number of packages in transmission Debug CAN bus tx parameter available in read only modality number of packages in reception err parameter available in read only modality number of packages in error Debug CAN bus ovf parameter available in read only modality number of packages in overflow Debug 5VP parameter available in read only modality reading ...
Page 52: ...I PRO 3 version and revision Info SN parameter available in read only modality information about the serial number and the result of the productive test Info MASK parameter available in read only modality information baout the mask it depends on the builder s coding system Info date and time parameter available in read only modality date and time of the last compilation of the application project ...
Page 53: ...t 1000 probe Parameters 1 AI5 NTC kind of probe analog input 5 PTC PTC probe NTC NTC probe 0 20mA 0 20 mA transducer 4 20mA 4 20 mA transducer 0 5V 0 5 V ratiometric transducer 0 10V 0 10 V ratiometric transducer PT1000 Pt 1000 probe Parameters 1 AI Err Time 0 240 s 2 analog inputs time out after this time without communication with an analog input the controller signals the analog input error Par...
Page 54: ...evel 2 keep pressed 3 s buttons LEFT and RIGHT to gain access to the first page of level 3 Parameters 2 press button RIGHT to show it Password Indi NO connection among the passwords to gain access to the levels NO one has not to set any password to gain access to levels lower than the one one has already gained access YES one has to set a password to gain access to each level Parameters 2 press bu...
Page 55: ...0 YYYY four numbers for example 2010 Parameters 2 press button RIGHT to show it not available in the blind versions Date format D M Y date format D M Y day month and year M D Y month day and year Y M D year month and day Parameters 2 press button RIGHT to show it not available in the blind versions Time Char Sep time separator ASCII character Parameters 2 press button RIGHT to show it not availabl...
Page 56: ...Baud 20K CANbus communication baud rate 20K 20 000 baud 50K 50 000 baud 125K 125 000 baud 500K 500 000 baud Networks CAN Bus Timeout 1 60 s 5 remote or with a device in the network CANbus communication time out after this time without CANbus communication with a device it is excluded by the network Networks CAN Bus NetworkNode 1 0 32 127 1 99 address of a remote or of a device in the network CAN n...
Page 57: ...foFram 1 127 3 maximum number of packages transmitted as master before giving the token Networks BMS 4 Device ID 1 4194303 108 identity in a BACnet MS TP multinetwork Networks UART1 1 Address 1 247 1 local or of the controller Modbus node address in a RS 485 network wired on the first RS 485 port Networks UART1 1 Baud Rate 9600 Modbus communication baud rate in a RS 485 network wired on the first ...
Page 58: ...9200 19 200 baud 28800 28 000 baud 38400 38 400 baud 57600 57 600 baud Networks UART2 2 Parity EVEN Modbus communication parity in a RS 485 network wired on the second RS 485 port NONE no parity ODD odd EVEN even Networks UART2 2 Stop 1 BIT Modbus communication stop bit number in a RS 485 network wired on the second RS 485 port 1 BIT 1 bit 2 BIT 2 bit Networks UART2 2 Timeout 2 240 s 10 Modbus com...
Page 59: ...e password to gain access to level 3 Password Level 3 ON enabling the password to gain access to level 3 OFF to gain access to level 3 one has not to set any password ON to gain access to level 3 one has to set a password 32768 32767 0 value of the password to gain access to level 4 Password Level 4 ON enabling the password to gain access to level 4 OFF to gain access to level 4 one has not to set...
Page 60: ... read only modality clock status ok not in error err in error low loss of data Diagnostic Power Supply parameter available in read only modality stack status ok not in error err in error because of overflow Diagnostic 5V Ratio parameter available in read only modality power supply voltage status ok not in error err in error because of out of range voltage Diagnostic 24V Sensor parameter available ...
Page 61: ...rameter available in read only modality misura della tensione di alimentazione Debug 5VP parameter available in read only modality reading the power supply voltage of the ratiometric transducers 24VP parameter available in read only modality reading the power supply voltage of the 0 20 mA 4 20 mA 0 10 V transducers Debug 24VE parameter available in read only modality reading the power supply volta...
Page 62: ...UNI PRO 3 version and revision Info SN parameter available in read only modality information about the serial number and the result of the productive test Info MASK parameter available in read only modality information baout the mask it depends on the builder s coding system Info date and time parameter available in read only modality date and time of the last compilation of the application projec...
Page 63: ...0mA 0 20 mA 4 20mA 4 20 mA 0 10V 0 10 V Parameters 1 AO3 0 10V kind of signal analog input 3 0 20mA 0 20 mA 4 20mA 4 20 mA 0 10V 0 10 V Parameters 2 press button RIGHT to show it I O Timeout 1 240 s 60 time out of the CANbus communication for the test of the remote values of the I O after this time without CANbus communication the I O of the expansion is disabled Networks CAN Bus MyNode 1 127 2 lo...
Page 64: ...of the power supply voltage of the ratiometric transducers ok not in error err in error because of out of range voltage Diagnostic 24V Sensor parameter available in read only modality status of the power supply voltage of the 0 20 mA 4 20 mA 0 10 V transducers ok not in error err in error because of out of range voltage Main time parameter available in read only modality main cycle time of the app...
Page 65: ...er of packages in overflow Debug 5VP parameter available in read only modality reading the power supply voltage of the ratiometric transducers Debug 24VP parameter available in read only modality reading the power supply voltage of the 0 20 mA 4 20 mA 0 10 V transducers Stack parameter available in read only modality minimum free stack Debug Buf parameter available in read only modality number of ...
Page 66: ...ls and as well as in all those applications where a frontal protection degree IP65 is required built in by wall in traditional box like 506 by BTicino by wall on the support CPVW00 by EVCO to order separately Also the necessity to customize the interface in order to integrate it aesthetically in residential and commercial environments is satisfied by Vgraph since at the front of the interface one ...
Page 67: ... ver 2 0 Code 114CP3E204 page 67 of 86 7 2 3 Size Size in mm in Size Minimum Typical Maximum A 104 0 4 094 104 0 4 094 104 8 4 125 B 70 0 2 755 70 0 2 755 70 8 2 787 C 22 0 0 866 23 0 0 905 24 0 0 944 D 40 8 1 606 41 8 1 645 42 8 1 685 ...
Page 68: ...required built in by wall in traditional box like 506 by BTicino by wall on the support CPVW00 by EVCO to order separately Also the necessity to customize the interface in order to integrate it aesthetically in residential and commercial environments is satisfied by Vtouch since at the front of the interface one can apply both the plates CPVP by EVCO to order separately made in plastic material an...
Page 69: ...ver 2 0 Code 114CP3E204 page 69 of 86 7 3 3 Size Size is in mm in Size Minimum Typical Maximum A 104 0 4 094 104 0 4 094 104 8 4 125 B 70 0 2 755 70 0 2 755 70 8 2 787 C 22 0 0 866 23 0 0 905 24 0 0 944 D 40 8 1 606 41 8 1 645 42 8 1 685 ...
Page 70: ...by BTicino by wall on the support CPVW00 by EVCO to order separately Also the necessity to customize the interface in order to integrate it aesthetically in residential and commercial environments is satisfied by Vroom since at the front of the interface one can apply both the plates CPVP by EVCO to order separately made in plastic material and available in two different colorations white and blac...
Page 71: ... ver 2 0 Code 114CP3E204 page 71 of 86 7 4 3 Size Size in mm in Size Minimum Typical Maximum A 104 0 4 094 104 0 4 094 104 8 4 125 B 70 0 2 755 70 0 2 755 70 8 2 787 C 22 0 0 866 23 0 0 905 24 0 0 944 D 40 8 1 606 41 8 1 645 42 8 1 685 ...
Page 72: ...ugh UNI PRO 3 The kit is made of TTL USB isolated serial interface USB cable to connect the serial interface to the Personal Computer TTL cable to connect the serial interface to the controller 8 1 2 Description The following drawing shows the aspect of the programming kit EVIF20TUXI The following table shows the meaning of the parts of the kit Part Meaning 1 USB cable 2 m 6 ft long 2 TTL cable 2 ...
Page 73: ... interface 4 Plug in the other end of the USB cable into an USB port of the Personal Computer For further information consult the Software manual of UNI PRO 3 8 2 Programming key EVKEY10 8 2 1 Introduction EVKEY10 is a programming key Through the key it is possible to make the upload and the download of the application software parameters and or of the configuration ones The key can be used both w...
Page 74: ...ctor for power supplier EVPS 8 2 3 Size Size is in mm in 8 2 4 Connection to the controller Operate as follows 1 Plug in the telephone connector of the key into the programming and debugging port of the controller To copy the parameters from the controller to the key and vice versa look at chapter 6 CONFIGURATION For further information consult the Software manual of UNI PRO 3 ...
Page 75: ... rail 35 0 x 7 5 mm 1 377 x 0 295 in or 35 0 x 15 0 mm 1 377 x 0 590 in according to EN 50022 Index of protection IP20 IP40 the front Connections c pro 3 hecto and c pro 3 hecto c pro 3 mega and c pro 3 NODE mega c pro 3 EXP hecto and c pro 3 EXP hecto male extractable screw terminal blocks pitch 5 0 mm 0 196 in power supply inputs outputs and CAN port for conductors up to 2 5 mm 0 0038 in 8 poles...
Page 76: ...ctable screw terminal blocks pitch 5 0 mm 0 196 in to order separately One suggests using the connecting kit CJAV16 female extractable screw terminal blocks pitch 5 0 mm 0 196 in to order separately To program the controller one has to use the programming kit EVIF20TUXI TTL USB isolated serial interface TTL cable 2 5 m 8 ft long USB cable 2 m 6 ft long to order separately One suggests using the co...
Page 77: ...o in corrente continua 10 VA max if the expansion is powered in alternate current 6 W max if the expansion is powered in direct current Real time clock c pro 3 hecto and c pro 3 hecto c pro 3 mega and c pro 3 NODE mega c pro 3 EXP hecto and c pro 3 EXP hecto incorporated with SuperCap battery Drift to 30 s month at 25 C 77 F not available Alarm buzzer c pro 3 hecto and c pro 3 hecto c pro 3 mega a...
Page 78: ...puts 990 Ω 25 C 77 F Kind of sensor KTY 81 121 Working range from 50 to 150 C 58 to 302 F Accuracy 0 5 of the full scale between 40 and 100 C 1 C between 50 and 40 C and between 100 and 150 C Resolution 0 1 C Conversion time 100 ms Protection no protection NTC analog inputs 10K Ω 25 C 77 F Kind of sensor β3435 Working range from 50 to 120 C 58 to 248 F Accuracy 0 7 of the full scale between 40 and...
Page 79: ...nput resistance to 10K Ω Protection no protection Optoisolated digital inputs at 24 VAC DC Power supply 24 VAC 15 50 60 Hz 3 Hz or 24 VDC 66 16 Input resistance to 10K Ω Protection no protection Displays c pro 3 hecto and c pro 3 hecto c pro 3 mega and c pro 3 NODE mega c pro 3 EXP hecto and c pro 3 EXP hecto signalling LEDs 122 x 32 pixel single colour LCD graphic display black with rearlighting ...
Page 80: ...e full scale for users having impedance of 5K Ω Resolution 0 01 V Conversion time 1 s Protection restorable thermal protection against the short circuit and the overload Digital outputs c pro 3 hecto c pro 3 mega and c pro 3 NODE mega c pro 3 EXP hecto 6 outputs electromechanical relays five 5 res A 250 VAC 6 000 cycles SPST outputs K1 K2 K3 K4 and K5 one 8 res A 250 VAC 6 000 cycles SPDT output K...
Page 81: ... K8 6 outputs electromechanical relays five 3 res A 250 VAC 6 000 cycles SPST outputs K1 K2 K3 K4 and K5 one 5 res A 250 VAC 6 000 cycles SPDT output K6 The devices ensure a double isolation among each terminal of the digital outputs and the remaining parts of the device Type of actions and additional features 1B Communication ports c pro 3 hecto and c pro 3 hecto c pro 3 mega and c pro 3 NODE meg...
Page 82: ...via application software 1 programming and debugging port 1 port for gateway c pro 3 plug in only in c pro 3 NODE mega Power supply user interface 24 VDC 122 mA max The controller incorporates a restorable thermal protection of the power supply against the short circuit and the overload 2 non optoisolated ports 1 CAN port with CANbus communication protocol 1 port to update the firmware of the expa...
Page 83: ..._____________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ________________________________________________________________________________________________...
Page 84: ...____________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________...
Page 85: ...ed by EVCO you can not publish it EVCO does not take any responsibility about features technical data and possible mistakes related in this document or coming by its use EVCO does not take any responsibility about damages coming by the non observance of the additional information EVCO reserves the right to make any change without prior notice and at any time without prejudice the basic safety and ...
Page 86: ...EVCO S p A c pro 3 Hardware manual ver 2 0 Code 114CP3E204 page 86 of 86 EVCO S p A Via Mezzaterra 6 32036 Sedico Belluno ITALY Phone 39 0437 85 24 68 Fax 39 0437 83 648 info evco it www evco it ...