![EVBox BusinessLine Installation And Commissioning Manual Download Page 29](http://html1.mh-extra.com/html/evbox/businessline/businessline_installation-and-commissioning-manual_2441701029.webp)
h. Tighten the four bolts.
i. Connect the connectors to the right side of the controller.
4.2.2. Connect power cables
See the corresponding illustrations in manual B.
Connection of the power input cable to a BusinessLine charging station depends on the model, as
shown in the following table:
Note:
Use minimum 2.5 mm
2
and maximum 16 mm
2
copper wire, depending on the power supply
available and the distance from the power supply cabinet.
Input type
RCBO
Power cable connection
Single socket charging station
1x 1-phase 230 V, 32 A
Yes
Direct to RCBO.
1x 3-phase 400 V, 16 A
Yes
Direct to RCBO.
1x 3-phase 400 V, 32 A
Yes
Direct to RCBO.
1x 3-phase 400 V, 32 A
No
To single terminal block.
Double socket charging station
4. Installation instructions
EN
25