Model: ZW31
Power:
120VAC, 60Hz
Frequency:
908.42 MHz
Maximum Load:
150W LED, 500W
incandescent
(300W with both sides of heat sink tabs off)
Minimum Load:
5W for LED bulbs
Range:
Up to 100 feet line of sight Operating
Temperature Range:
32-104° F (0-40° C)
For indoor use.
Specifications subject to change without notice
due to continuing product improvement
Approval: Z-Wave Plus Certified
switch x1
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applica-
tions. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication.
Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this
association automatically after inclusion.
Lifeline association only supports the “Device Reset Locally” function. Refer to the instructions of your controller for any available details on how this
can be set.
wallplate x1 wiring x1 screws x2
Part 1. Introduction
Contents
A quick note before we give out the wiring schematics. Please do not try installing this device if you are unsure of how electrical circuits operate
within your home. As exciting as it is to have a smart switch installed, it can be dangerous and even life-threatening if you do not install this
correctly. Please consult a qualified electrician if necessary. With that said, here are a few other warnings we’d like to point out for your safety:
A Few Quick Reminders
Note before installation
1) The Z-Wave In-wall Smart Switch must not exceed
150W LED, 500W
incandescent.
2) The switch box required: 1-gang U.S. wall box.
3½ in
deep recommended,
2¼ in
deep minimum.
(
The switch is designed only for use
with permanently installed fixtures.
)
3) Work with
regular 3-way on/off
for 2 locations control. It can only be connected with regular 3-way on/off switch,
don't use a smart
switch or a dimmer switch! Couldn't work with an add-on switch!
4) The colors of your wires may not match the ones in our diagrams so please make sure you've
identified all wires correctly
based on
their source, not color only.
5) Please check your original 3-way wiring circuit in your home before installation, and then
follow the wiring diagram option 1 or 2
in
the manual.
6) Install the smart switch in the switch box which directly connects to the power
Line and Neutral.
7) This switch
requires a Neutral for installation
, or the installation will not succeed.
8) Not recommended for fan.
Convention
Description
Convention
Description
• Locally button function
• LED indicator status setting
• Auto Turn-On/Off timer
• Association setting parameter
• Restore state after power failure
• Light off state setting
• Button function setting
• Multilevel minimum value can be set
• Association group
• Generic device class
• Command classes
Function description
• LED indicator/ Button function
• Adding / reset the device ( Factory setting)
• Min & Max Brightness Value Setting
• Wiring instructions
•
Single pole and 3-way wiring diagram
• Product introduction
• Installation steps
Part 1.
Introduction
Part 2.
Wiring Diagram
Part 3.
Manual Control
•
Solutions to some common problems
Part 4.
Troubleshooting
CHANGING THE COLOR OF THE PADDLE(OPTIONAL)
This step is optional. Before you start you may want to change the color of the
paddle to match your wallplate or decor.
1. Push side tabs in on one side and then the other to release paddle. Lift the
cover up and off.
2. Simply put the new paddle onto the switch by side tabs and snap securely
into place.Once this step has been completed please proceed to part 2 wiring.
If you have any questions, please contact us at
HOW TO INSTALL THE WIRES
3.
STRIP WIRE AT 3/8-1/2”
1. Unscrew:
carefully turn the screw counterclockwise to leave enough space for
the wire to be inserted. Do not unscrew the screws completely.
2. Press down:
Once loosened, use your finger so it catches the thread.
3. Insert the wire:
make sure the wire is completely straight, then insert it into the
terminal while holding down the screw. Do not wrap the wire around the screw!
4. Tighten:
Turn the screw clockwise to tighten the wire. Make sure the
wires are locked!
Note:
There are 2 holes for each terminal can be used in the
connection.You can use a jump wire or the second hole at the
terminal to connect.
2.
Line (hot) — black (connected to power)
Neutral — white
Load — black (connected to lighting)
Traveler — red/other
(only in 3-way installations)
Line
Load
Ground
Traveler
Neutral
1.
4.
Basic Operation
The connected light can be turned ON/OFF in two ways:
1. Manually from the front panel of the In-wall Switch
2. Remotely with a Z-Wave Controller
Manual Control
The Front Panel Paddle Switch allows the user to:
Turn ON/OFF the connected fixture
Single-pole wiring
3-Way switch option 1
1)
Neutral required
. If the box do not have a Neutral,
please stop! Connect the
white wire to neutral
terminal
(use a white jump wire form the package
or
the second hole at the terminal to connect.)
2) Insert the Line wire to Line terminal and Load wire to
Load terminal.
LOAD and LINE Can’t be swapped
,
please make sure to identify them correctly!
IMPORTANT
1. Tool:
Please prepare a flat head screwdriver.
2.
Turn power OFF at circuit breaker or fuse box.
3.
Remove wallplate.
4. Remove the switch mounting screws.
5.
Disconnect the wires and label them after remove
the old switch
.(Please use our sticker)
6. Carefully remove the switch from the switch box.
(DO
NOT disconnect the wires.)
7. There are up to five screw terminals on the smart
switch, these are marked
(Please check
<HOW TO
INSTALL THE WIRES>
)
8. Fix the wallplate with screws after wiring succeed.
(Please use our screws.)
9.The Ground was excluded from the diagram to
simplify the illustration.
Please Make sure all ground
wires are connected to all switches respectively.
Line
Load
Ground
Neutral
Traveler
(Just for 3-way switch)
1)
Neutral required
. If the switch box do
not have a Neutral, please stop!
Connect the
white wire to neutral
terminal
(use a white jump wire form
the package or the second hole at the
terminal to connect.)
2) Insert the Line wire to Line terminal
and Load wire to Load terminal.
LOAD and LINE Can’t be swapped
,
please make sure to identify them
correctly!
3) Install the smart switch in the switch
box which directly connects to the
power
Line, Load and Neutral.
4)
Only work with
regular 3-way on/off
for 2 locations control. It can only be
connected with regular 3-way on/off
switch,
don't use a smart switch or a
dimmer switch! Couldn't work with
an add-on switch!
Power
Power
regular 1
regular 2
common
common
Line
Load
Neutral
Traveler
From source
(3-way switch)
IMPORTANT
Neutral
Line
Neutral
Line
Smart
Switch
OUT TO LIGHT
regular
Line
Load
Neutral
From source
Ground
Load
Neutral
Line
Traveler
Line
Load
Neutral
From source
Neutral
OUT TO LIGHT
OUT TO LIGHT
Ground
Load
Neutral
Line
Traveler
regular
common
None-connection
Line
Load
Neutral
Traveler
From source
( Line/Hot Neutral and Light/Load)
(3-way switch)
Box 1
Don’t change this
regular 3-way on/off switch
Box 2
OUT TO LIGHT
3-Way Z-Wave Smart Dimmer Switch
• ZW31 •
Part 5.
Parameter Settings
Part 2. Wiring Diagram
Air-Gap Switch:
The "air gap switch" will cut power to the device if it's pulled up. It's located
right below the main switch itself, often next to the LED. Pull up for Bulb
replacement, push down for normal use.
Neutral
Line
Neutral
Line
Smart
Switch
common
common
common
For more detials, please refer to the manual parts.
If you have any questions during installation,
Please contact us