Instructions 

L30C-30A-UK-02-01 

 
 
 

QUICK GUIDE 

 

SE30 CONTROL PANEL 

 

SOFTWARE VERSION 30ROS02___ 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.  DATA 

 
 

 

Nominal operating voltage............................................................. 24  VDC 

 

 

Allowed supply voltage.......................................................20.4-28.8  VDC 

 

 

Maximum current consumption ..................................................... 80  mA at 24 VDC 

 

 

Digital input.................................................................................... 12 

 

 

Digital output, direct......................................................................... 9 

 

 

 

Maximum current, reserve.......................................................... 1  A 

 

 

 

Voltage ..........................................................................20.4-28.8  VDC 

 

 

Digital output, potential-free ............................................................ 5 

 

 

 

Maximum current........................................................................ 1  A 

 

 

 

Maximum voltage ..................................................................... 30  VDC 

 

 

Total maximum current, outputs...................................................... 5  A 

 

 

Analog input..................................................................................... 2  4-20 mA 

 

 

Analog output .................................................................................. 1  4-20 mA 

 

 

Protection class ..........................................................................IP54 

 

 

Ambient temperature ..................................................................0-50  °C 

 

 

Storage temperature .........................................................-20 to +60  °C 

 

 

Relative humidity ......................................................................10-80  %, non-condensing 

 
 

Summary of Contents for SE 30

Page 1: ...24 VDC Allowed supply voltage 20 4 28 8 VDC Maximum current consumption 80 mA at 24 VDC Digital input 12 Digital output direct 9 Maximum current reserve 1 A Voltage 20 4 28 8 VDC Digital output potential free 5 Maximum current 1 A Maximum voltage 30 VDC Total maximum current outputs 5 A Analog input 2 4 20 mA Analog output 1 4 20 mA Protection class IP54 Ambient temperature 0 50 C Storage temperat...

Page 2: ...C 30A UK 02 01 1 May 2009 2 ELECTRICAL CONNECTION AND INSTALLATION RUN CPU is active SC CPU error I0 I11 Digital input O0 O15 Digital output F1 fuse for CPU T1A 5 x 20 mm F2 fuse for outputs T5A 5 x 20 mm ...

Page 3: ...valve T1 11 12 I5 Block automatic regeneration 35 36 O5 Outlet valve T2 13 14 I6 Pressure switch 37 38 O6 RO inlet valve 15 16 I7 Block operation 39 40 O7 RO quality rinse valve 17 18 I8 RO pump in operation 41 42 O8 RO pump 19 20 I9 RO protective motor switch disconnected 43 44 O9 Alarm potential free 21 22 I10 Conductivity OK 45 46 O10 Dosing potential free 23 24 I11 Alarm reset 47 48 O11 Output...

Page 4: ...red value on the numeric keypad Press ENTER to confirm your entries Special functions can be enabled or disabled These functions are displayed with when enabled and when disabled Press ENTER to select a function and the symbols blink Now press ENTER again to confirm your selection If you want to disable a function the procedure is the same If the control is in configuration menu and the keypad has...

Page 5: ...L30C 30A UK 02 01 4 May 2009 ...

Page 6: ...n as text on the display and as red LED alarm Press ENTER to acknowledge an alarm Regeneration of the softening plant can be started manually by depressing key 0 and at the same time pressing down key 1 for approximately two seconds It is also possible to step through the phases by depressing key 0 and pressing down key 2 for approximately two seconds If the RO plant is in start up it is also poss...

Page 7: ...as been so for so long that a planned stand by rinse is performed 10 minutes and 00 seconds of the rinse remain Softening operation The softening plant is in operation and can supply 9 9 m of softened water before regeneration Tank 1 is the next to be regenerated The character before T1 is an indicator of the pulse water meter When a pulse is registered the character changes to vertical for a shor...

Page 8: ...59 RO stand by Set the duration of stand by time Value is set as whole hours and can be from 1 to 45 Stand by time is the interrupted time in which the plant is not in operation If the plant is out of operation longer than the stand by time a rinse is performed RO rinse Set the duration of rinse after stand by time Value is set as whole minutes and can be from 1 to 59 If during rinse the RO plant ...

Page 9: ...nge for the analog outlet Only calibration of the analog output signal is possible 4 mA point Set the desired value applicable to 4 mA on output Possible setting from 9 9 to 25 µS cm 20 mA point Set the desired value applicable to 20 mA on output Possible setting from 25 to 75 µS cm Number of tanks in softening plant Set the number of tanks on the softening plant Possible setting 1 or 2 If one tan...

Page 10: ... pressing the keys 0 and 1 or 0 and 2 respectively Softening reset capacity If regeneration of the softening plant is started manually the capacity is not reset automatically It is possible to do so manually Factory setting The set values are changed to factory setting Select language Among these languages select the desired display language 01 English UK 02 German DE 03 Danish DK 04 French FR 05 ...

Page 11: ...L30C 30A UK 02 01 10 May 2009 ...

Page 12: ...y of our own make We continuously supply spare parts for more than 25 year old plants Consumables Water softening salt Test kits for periodical hardness control after the softening plant Filter media for pressure filters Ion exchange resins Membranes for reverse osmosis plants Filter bags UV lamps Temporary Needs In case of emergency or temporary needs we offer a wide range of rental units All uni...