background image

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

MicroCal T100+ 
MicroCal T500+ 
MicroCal T1100+ 

Portable Temperature Calibrators 

Instruction Manual MM850518 Ed.01 

 

 
 
 

Summary of Contents for MicroCal T100+

Page 1: ...MicroCal T100 MicroCal T500 MicroCal T1100 Portable Temperature Calibrators Instruction Manual MM850518 Ed 01...

Page 2: ...plies instructions and operative procedures for any operation on the instrument We recommend to contact our technicians for any support requirements MicroCal T is fully tested in conformity with the d...

Page 3: ...emoval of packaging 14 5 1 2 Positioning the calibrator 14 5 1 3 Supply 14 5 1 4 How to fit the equalising block in MicroCal T1100 14 6 OPERATION PROCEDURE 16 6 1 Operation description 16 6 2 Descript...

Page 4: ...____ _________________________________________________________ Instruction Manual MM850518 ed 01 ______________________________________________4_______________________________________________ 10 2 Let...

Page 5: ...otection 2 5A T fuse 3A F for 100 115V Calibrator measurements 160x370 x h 330 mm Measurements of case 520x330 x h 500 mm Weight 10 Kg only calibrator 17Kg with travelling case Structure in flanged pl...

Page 6: ...rate 20 22 C 1 Maximum descent rate 8 12 C 1 t 300 C Weight of calibrator 17Kg Test wells with perforation standard or by request Model with aluminium block measuring 65mm diameter Operative range Env...

Page 7: ...___ _________________________________________________________ Instruction Manual MM850518 ed 01 ______________________________________________7_______________________________________________ afterward...

Page 8: ...re regulator Manual resetting safety thermostat The internal oven consist of a quartz tube hearted by a ceramic resistance all mounted in an aluminium structure Standard insert Inconel made 44mmx175mm...

Page 9: ...5 100 Vac with Japan USA plug Table C Calibration Certificate 1 Eurotron certificate 2 2 MicroCal T500 Cat 8174 A B C Table A Options 0 None 1 Aluminium carrying case EE880063 2 Extended temperature r...

Page 10: ...tion Manual MM850518 ed 01 ______________________________________________10_______________________________________________ 2 230 Vac Schuko plug 3 240 Vac UK plug 4 230 Vac European plug 5 100 Vac wit...

Page 11: ...Check that the diameter of the hole in the calibration block is 1 at least 0 5mm bigger than the diameter of the probe for diameter of the probe up to 8mm 2 at least 0 7mm bigger than the diameter of...

Page 12: ...uction Manual MM850518 ed 01 ______________________________________________12_______________________________________________ instability and breakage of the sensitive element For the calibration of te...

Page 13: ...move the block from the quartz tube in order to prevent breakage of the tube It is a good idea if these operations are carried out with the calibrator as close to ambient temperature as possible Never...

Page 14: ...ac 110 100V by request 50 60Hz A 2 5mt cable is supplied with the calibrator fitted with 2 conductors plus earth Make sure that the plant is earthen correctly before switching the instrument on 5 1 4...

Page 15: ...________________________________________15_______________________________________________ COMMAND LIST POS DESCRIPTION 1 SUPPLY SOCKET 2 MAIN SWITCH 3 PROTECTION FUSES 4 SWITCH TEST BUSHES 5 RS 232 SO...

Page 16: ...the set parameter The thermoregulator is endowed with eight bushes 13 that can be set as Pt100 or Tc 6 2 2 Main switch The main switch 2 is found on the rear of the instrument it is fitted with a soc...

Page 17: ...will check to see if it is feasible This will avoid any unfortunate problems which might arise if the wrong tolerances are used 6 2 7 Temperature sensors The temperature sensors used for regulating a...

Page 18: ...e set point value Press the E key to confirm the chosen value Wait for the stabilisation of the oven before starting any calibration symbol on the fist line of the display To working at different temp...

Page 19: ...ossible to control the intervention point of thermostats by the SWITCH TEST function Insert the thermostat s end in the most suitable hole of the calibrator pit refer to notes in paragraph 3 Connect t...

Page 20: ...________________________________ _________________________________________________________ Instruction Manual MM850518 ed 01 ______________________________________________20___________________________...

Page 21: ...t is cut off The safety thermostat 10 has been triggered The thermoregulator 7 is not generating a signal Replace the static relay Contact our technical office Replace the thermoregulator 4 The displa...

Page 22: ...ocedure enabling disabling Select ON by the 5 or 6 key and confirm the choice by pressing the E key the oven will reach the set SP2 temperature with the set gradient starting from the same temperature...

Page 23: ...RIS 0 1 0 01 Display reading resolution the values admitted are 0 1 C and 0 01 C and they can be selected by the 5 or 6keys For this parameter it is not necessary to confirm the choice SW ON Switch on...

Page 24: ...he task of reducing the error EXT SENSOR TYPE J R S PT3W PT N K This parameter allows selecting the kind of sensor read by the display and connected to the four bushes of input 1 Units C F This parame...

Page 25: ...oice by the E key S N Equipment serial number It is set by the manufacturer and cannot be changed by the user STANDARD SYSTEM It indicates whether the system is only designed to heat or if it is a Pel...

Page 26: ...____________________ Instruction Manual MM850518 ed 01 ______________________________________________26_______________________________________________ 9 MICRO PROCESSOR REGULATOR DEFAULT VALUES SET BY...

Page 27: ...uthorised modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion or current heat moisture or v...

Page 28: ...______________________________ _________________________________________________________ Instruction Manual MM850518 ed 01 ______________________________________________28_____________________________...

Page 29: ...Manual MM850518 ed 01 ______________________________________________29_______________________________________________ A1 EMC Conformity The Pressure Module case is made in aluminium to fulfil the pre...

Page 30: ...dress declare under our sole responsibility that the product Dry Block Temperature Calibrator type MicroCal T100 T500 T1100 Name and type cat 8172 8174 8176 Model to which this declaration relates is...