5.7
Correction of supply current
Attention in case of continous load:
Due to the capacitive input impedance of
DC-Bus, the input current is deformated.
This guides to RMS -values higher than the sinus-based calculated values. Fuses,
contactors and line filters have to be selected in respect to this effect.
In typical servo application with Stop/Go-operation (S3-Operation), the
rating to nominal data will be sufficient.
In other cases, the value has to be corrected using the following diagram.
1,0
1,2
1,4
1,6
1,8
2,0
2,2
Correction-Factor
Iac sinus calculated
[A]
5
10
15
10
20
30
13
26
637+/KD6R02..10.S4-7
637+/KD6R16..30.S3-7
637+/KD6R02..10.S3-3
2,5
7,5
12,5
5
15
25
6,5
19,5
2,4
1-Phase Supply 637+/ KD6R02..06.S4-3
Example
3-Phase Supply
Example:
Drive type 637+/KD6R16.S4-3 is supplied by AC 230V 3-ph.
Output data to the motor: AC 200V 16A
Output-power: Pout = 200V x 16A x 1,73 = 5,54 kW
This output-power must be generated by:
calculated supply-current Iac sinus =5,54kW / (230V x 1,73) = 13,9 A
Correction-Factor from diagram: 1,6
RMS. Supply-Current Ieff = Iac sinus x 1,6 = 22,3 A
Result
:
All supply-equipment has to be selected in respect tothe enhanced current.
Summary of Contents for 637+/D6R KD6R
Page 78: ...78 Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc Certificates ...
Page 79: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 79 Certificates ...
Page 80: ...80 Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc Certificates ...
Page 81: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 81 Certificates ...
Page 82: ...82 Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc Certificates ...
Page 83: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 83 Certificates ...
Page 85: ...Product manual Model 637 D6R KD6R 07 02 09 01 E V0402 doc 85 16 Notes ...