TECHNICAL SPECIFICATION (RECORDER) (Cont.)
Electromagnetic compatibility (EMC)
Emissions and immunity:
BS EN61326
Electrical safety
BS EN61010.
Installation category II, Pollution degree 2
Power requirements
Supply voltage
Standard:
85 to 265 volts; 47 to 63 Hz or 110 to 370V dc (dc supply not to be used if isolated transmitter power supply fitted)
Low voltage option:
20 to 42V RMS; 45 to 400 Hz, or 20 to 54V dc (option not to be used if isolated transmitter power supply fitted)
Power (max.)
60 VA (Inrush current 36A)
Fuse type
None
Interrupt protection
Standard:
Holdup >200msec. at 240V ac, with full load.
Low voltage option:
20msec at 20Vdc or RMS, with full load
Back-up battery
Type
Current recorders:
Poly-carbonmonofluoride/lithium (BR2330). Part Number PA261095 - see Annex D .
Older recorders:
Lithium Manganese (CR2032). Part Number PA250983 - see Annex B, section B3.2
Support time
A fully-charged, new battery supports the Real-Time Clock for a minimum of 1 year with the recorder unpowered
Replacement period
3-years
Stored data
Time; date; values for totalisers, counters and timers; batch data; values for those maths functions with history, such as
Fvalue, Rolling average, Stopwatch etc.
Clock (RTC) data
Temperature stability
0 to 40˚C:
-3 to +2 ppm
-40 to + 85 ˚C:
±
7.5 ppm
Ageing
±
1 ppm per year
Touch screen
Colour TFT LCD with cold-cathode backlighting, fitted with resistive, analogue, touch panel
Screen specification
Small frame:
1/4 VGA Resolution = 320 x 240 pixels
Large frame:
SVGA Resolution= 800 x 600 pixels
Update information
Input/relay output sample rate:
8 Hz.
Display update:
1 Hz,
Archive sample value:
Latest value at archive time
Trended/displayed value:
Latest value at display update time
Network Communications
Type
IEEE802.3 10BaseT
Cable
Type:
CAT5
Maximum length:
100 metres
Termination:
RJ45
Serial communications option
Isolation (dc to 65Hz BS EN61010)
Installation category II; Pollution degree 2.
Terminals to ground:
100 V RMS or dc (basic insulation)
Transmitter power supply (Isolated) (100 mm recorders only)
Number of outputs
Three
Output voltage
25V nominal
Max. current
20mA per output
Isolation (dc to 65Hz BS EN61010)
Installation category II; Pollution degree 2.
Channel to channel:
100V RMS or dc (double insulation)
Channel to ground:
100V RMS or dc (basic insulation).
Fuse (20mm Type T)
Supply voltage = 110/120Vac:
100 mA
Supply voltage = 220/240Vac: