background image

 

 

 

 

WINNER 

Dual Channel Fixed Cellular GSM Gateway 

User Manual 

 

Version 5.2 

Summary of Contents for Winner Series

Page 1: ...WINNER Dual Channel Fixed Cellular GSM Gateway User Manual Version 5 2...

Page 2: ...Interference to Medical and Personal Electronic Devices 6 2 5 Antenna Considerations 6 3 INSTALLATION STAGES AND PROCEDURES 7 3 1 STAGE 1 Identifying Potential Sources of Interference 7 3 2 STAGE 2 As...

Page 3: ...WINNER gateways are therefore an essential tool for cutting overhead costs of telephone bills as they allow direct access to the GSM networks and cut costs of airtime and interconnections The WINNER...

Page 4: ...se to extreme temperatures optimal operating temperatures 5 C to 50 C Position equipment in a stable environment any sudden fall or sharp movement may damage the device Do not cover or stick any forei...

Page 5: ...R GATEWAY UNIT 1 Install the CD launch program on the computer 2 Connect the RJ 45 Plug of the com cable to one of the ports Master or Slave Connect the D type connector to an available COM outlet on...

Page 6: ...metallic strip back into place 2 4 INTERFERENCE TO MEDICAL AND PERSONAL ELECTRONIC DEVICES Most electronic equipment is shielded from RF energy Nevertheless RF energy from the WINNER transmitter may...

Page 7: ...telephone away from the WINNER If moving it farther away has no effect try using a different telephone The WINNER is a two way radio and as such some occasional interference is unavoidable For best re...

Page 8: ...nce thus once you turn the power on make sure you have good reception and clear conversation with the unit 3 Insert the SIMs as follows On the bottom of the Dual Cell open the SIM chambers by sliding...

Page 9: ...2 Amp 6 Wait 30 seconds for the unit to startup Testing When you see the operator provider name on the LCD try to make an outgoing call you should see the number dialed Make a call to the unit from a...

Page 10: ...4 1 INSTALLINGTHE PCSOFTWARE 1 Insert the Winner 5 2 Installation CD into to CD drive of the PC 2 In Windows Explorer navigate to the installation CD drive 3 Double click on to install the Winner 5 2...

Page 11: ...ner Dual Channel Fixed Cellular GSM Gateway User Manual 11 5 Click Next The Ready to install the program window will open 6 Click install Wait until the software installation complete message will app...

Page 12: ...the Type of Connection between the PC and the Gateway as described below 1 Launch the software by pressing on your PC desktop or by pressing Start Programs Eurotech Communication WINNER V5 2 W 3 6 2 T...

Page 13: ...n status When connected you see the status Connected and one of the led image on the bottom right will be green 7 The Time is the time and date the gateway is set to 8 The Gateway Ver is the firmware...

Page 14: ...nutes but the call will go out only if the prefix is in the current SIM prefix table SIM Times The gateway will count the calls minutes When the count at the end of a call will reach the SIM Timer in...

Page 15: ...Select the Maximum Digits Dialed for a valid number 11 Select On in the Data Mode to send and receive data through the module Select Off to work in voice mode 12 Select On in the Setup CID to generate...

Page 16: ...t send Caller ID CLIR Suppression The gateway send Caller ID 5 Select in the Network specific network for the SIM to work with 6 Enter the PIN Code of the SIM Needed only when the SIM demand a PIN Co...

Page 17: ...for each SIM Prefix Press Write Tariffs These numbers are divided by the base tariff to get the pulses per minute Example Base Tariff is set to 4 Sim1 prefix1 is set to 20 Pulses per minute 20 4 5ppm...

Page 18: ...ss the buttons to change the time of the gateway Backup and Restore of the Setting 1 Press the Backup Data to File Button and choose a file to store all the settings of this port 2 Press the Restore D...

Page 19: ...85 C Analog Telephone Analog PBX interface Tip Ring Voltage 48V Line current 25ma Ringing Voltage 140 Vpp Load 3REN Crest Factor 1 25 Frequency 20 Hz Cadency 2s 4s Answer supervision Reverse polarity...

Page 20: ...requency 400Hz Level 2dB Cadence continuous 4 1 4 CONGESTION BUSYTONE Frequency 400Hz Level 2dB Cadence 500ms 20 signal 500ms 20 pause 4 2 ENVIROMENTAL CHARACTERISTICS The WINNER complies to the follo...