background image

Original User Manual

ReliaGATE 10-05-34

Multi-Service Gateway & Edge Controller

Rev. 1-0 — 13 May 2016 — REGATE-10-05-34_UserMan_EN_1-0 — ENGLISH

Summary of Contents for ReliaGATE 10-05-34

Page 1: ...Original User Manual ReliaGATE 10 05 34 Multi Service Gateway Edge Controller Rev 1 0 13 May 2016 REGATE 10 05 34_UserMan_EN_1 0 ENGLISH...

Page 2: ...rademarks and registered trademarks are the property of their respective owners Revision history Revision Description Date 1 0 First release 13 May 2016 2016 Eurotech SpA Via Fratelli Solari 3 A 33020...

Page 3: ...1 FCC Class A notice 17 6 2 RoHS compliance 17 6 3 WEEE compliance 17 7 Technical Specifications 19 8 Getting started 21 9 Product interfaces 23 9 1 Front panel interfaces 23 9 1 1 DIP switch selecto...

Page 4: ...3 Modem 41 12 4 COM ports 0 and 1 Console port 41 12 4 1 How to test a COM port 41 12 5 LED indicators 42 12 5 1 How to manage a LED 42 12 6 Flash Memory 43 12 7 RTC 44 12 7 1 How to manage the times...

Page 5: ...the ReliaGATE 10 05 34 using the DIN Rail Mounting Kit 56 16 2 1 How to replace the Mounting Bracket with the DIN Rail Mounting Kit 56 16 2 2 How to install the ReliaGATE 10 05 34 on a DIN rail 58 16...

Page 6: ...This page has been intentionally left blank...

Page 7: ...re or damage to equipment observe the following precautions as well as using good technical judgment whenever installing operating the product 1 1 Signals used in this document DANGER INDICATES A HAZA...

Page 8: ...accuracy and consistency with the hardware and software described Always refer to the latest available manual revision available at www eurotech com 1 3 Intended audience This document is intended fo...

Page 9: ...nd safety instructions Failure to supply power correctly or failure to follow all operating instructions correctly may create an electric shock hazard which could result in personal injury or loss of...

Page 10: ...This page has been intentionally left blank...

Page 11: ...w to receive technical support If you have technical questions or if you cannot isolate a problem with your product or for any inquiry about repair and returns policies contact l The Eurotech Global S...

Page 12: ...This page has been intentionally left blank...

Page 13: ..._P Positive signal in differential pair _N Negative signal in differential pair 4 2 Abbreviations for direction and electrical characteristics of a signal Convention Description I Signal is an input...

Page 14: ...This page has been intentionally left blank...

Page 15: ...rge protected USB port An internal battery provides up to 30 50 minutes of uptime and allows for a safe system shutdown in case of a blackout The ReliaGATE 10 05 34 can be equipped with Everyware Soft...

Page 16: ...1 0 16 62 5 1 Product labels The product label is placed on the bottom side of the product Ref Label content Label example 1 ReliaGATE model number ReliaGATE serial number WEEE symbol CE mark Ethernet...

Page 17: ...ion manual Modifications it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will...

Page 18: ...ould be installed and operated with minimum distance of 20 cm between the radiator and your body 6 2 RoHS compliance The product described in this document including all its components and its sub ass...

Page 19: ...this electrical and electronic equipment EEE that has been placed on the market after 2005 This product at the end of its life cycle must be collected separately and managed in accordance with the pro...

Page 20: ...Li ion Battery 3 7V 48mAh Safe shutdown and Power state restore LEDs 1xPower 1xCellular activity 2xUser configurable Buttons 1xReset 1xProgrammable SIM slot 1xMicroSIM user accessible Power Input Nom...

Page 21: ...ReliaGATE 10 05 x4 User Manual Rev 1 0 8 Getting started 21 62...

Page 22: ......

Page 23: ...d on a Yocto framework and supports login via a variety of methods For further information see l The Software on page 39 l How to log in the Administration Console on page 49 l How to access the inter...

Page 24: ...This page has been intentionally left blank...

Page 25: ...nnector Connector Base strip Header 8 pin 3 5 mm pitch Mating connector Pluggable screw terminal block 8 pin 3 5 mm pitch Example Shenzhen Connection Electronics Co Ltd P N PLTB1 5 08 BF 3 50 GY Table...

Page 26: ...scription Connector Mating connector information 1 Cellular antenna connector Connector Female SMA Mating connector Male SMA 2 USB 0 host port Connector USB Type A socket Mating connector USB Type A p...

Page 27: ...OWER LED ON ReliaGATE powered by the external source LED OFF ReliaGATE not powered by the external source Blue 2 CELL Cellular modem activity LED ON means modem ON LED blinking means modem attached to...

Page 28: ...faces The interfaces available behind the service panel are the following Figure 9 4 Service panel interfaces layout Ref Description 1 Reset pushbutton 2 Programmable pushbutton 3 TBD 4 Console port 5...

Page 29: ...IN P Positive power supply input 2 Power IN P Negative power supply input 10 1 3 How to turn ON the ReliaGATE 10 05 34 To turn the ReliaGATE 10 05 34 ON supply power to Pins 1 and 2 The system automat...

Page 30: ...34 User Manual Rev 1 0 28 62 10 1 6 How to perform a power reset of the ReliaGATE 10 05 34 To trigger a hardware reset of the ReliaGATE 10 05 34 push the reset pushbutton available behind the Service...

Page 31: ...DQPSK DBPSK CCK 802 11g n OFDM 64 QAM 16 QAM QPSK BPSK Data Rate 802 11b 1 2 5 5 11 Mbps 802 11g 6 9 12 18 24 36 48 54 Mbps Data Rate 20 MHz Long GI 800 ns 802 11n 6 5 13 19 5 26 39 52 58 5 65 Mbps D...

Page 32: ...5 kb s EDGE Class 12 MCS1 9 up to 236 8 kb s CSD GSM max 9 6 kb s UMTS Max 64 kb s SMS MT MO PDU Text mode Protocols Embedded TCP IP UDP IP HTTP FTP SSL Secure Socket Layer Network Jamming detection...

Page 33: ...ETH0 10 5 1 Connector pinout Pin Name Type Description 1 TX O Transmit Data 2 TX O Transmit Data 3 RX I Receive Data 6 RX I Receive Data 10 5 2 Port specifications Feature Description Network Standard...

Page 34: ...rt The ReliaGATE 10 05 34 provides one USB 2 0 host port For power supply only This interface is available on the rear panel and is noise and surge protected 10 6 1 Connector pinout Pin Name Type Desc...

Page 35: ...RS 485 fail safe and termination resistors To insert the RS 485 fail safe and termination resistors use the DIP switch selector located on the front panel sliding levers 1 to 3 The sliding levers hav...

Page 36: ...nnector located on the front panel pins 3 to 8 Pin Name Type Description 3 COM 0 RS 485 A I O COM port 0 RS 485 l A Line 4 COM 0 RS 485 B I O COM port 0 RS 485 l B Line 5 COM 0 GND P COM port 0 RS 485...

Page 37: ...erfaces in detail 10 8 The MicroSD card receptacle The ReliaGATE 10 05 34 includes a push push type Micro SD card receptacle behindthe Service Panel Insert the Micro SD card as in the picture below wi...

Page 38: ...ial port You can use it to access the Operating System 10 9 1 Connector and mating connector specifications Connector Shrouded header 3 pin 1 25 mm pitch Mating connector Receptacle Housing 3 pin 1 25...

Page 39: ...not come from the CPU SoC l It is the default RTC used by Linux to set and get the Wall time while booting up and while suspending resuming l It has an accuracy of 25 minutes per year at 25 C l It ca...

Page 40: ...le the watchdog use the DIP switch selector located on the front panel sliding lever 5 The sliding lever has the following meaning Lever Description 5 ON Watchdog disabled OFF Watchdog enabled default...

Page 41: ...kernel boot zImage and the device tree boot reliagate 10 11 dtb and boots the operating system up 11 2 1 How to select the Linux kernel sources U boot can execute the Linux kernel from either one of t...

Page 42: ...This page has been intentionally left blank...

Page 43: ...poses the modem as follows l AT commands port data communication dev ttyACM0 To turn the modem OFF unconditionally use the following commands echo 1 sys class gpio gpio30 value sleep 0 5 echo 0 sys cl...

Page 44: ...l LED 1 Reserved l LED 2 sys class gpio gpio114 value l LED 3 sys class gpio gpio115 value l LED 4 sys class gpio gpio116 value 12 5 1 How to manage a LED Each LED is managed by its respective GPIO E...

Page 45: ...ser Manual Rev 1 0 12 How to access the interfaces under Linux 43 62 12 6 Flash Memory The ReliaGATE 10 05 x4 exposes the flash memory as follows l Internal flash eMMC memory dev mmcblk0 l MicroSD car...

Page 46: ...successful initialization has been achieved You can only read and reset the timestamp registers To read the timestamp2 use the following command cat sys class rtc rtc1 device timestamp2 To reset the t...

Page 47: ...ReliaGATE 10 05 34 4 September 2015 at 10 00 AM 2 Tells the ReliaGATE 10 05 34 to automatically wake up 20 seconds after the specific date and time 3 Makes the ReliaGATE 10 05 34 enter sleep mode set...

Page 48: ...imeout in seconds Check if lasdt boot is caused by watchdog If ioctl fd WDIOC_GETBOOTSTATUS bootstatus 0 bootstatus 0 Watchdog bootstatus 0 Power on reset set the watchdog value for example 30 seconds...

Page 49: ...ed with a programmable pushbutton The programmable pushbutton is sensed by a Linux daemon which executes a shell script every time the button is either pushed or released To export the pushbutton use...

Page 50: ...This page has been intentionally left blank...

Page 51: ...5200 8 bits 1 stop bit no parity and no flow control 4 Connect the power supply to the ReliaGATE The Power LED lights when power is successfully connected 5 Via the Uboot bootloader the Linux kernel i...

Page 52: ...ow to change your security settings For security reasons Eurotech recommends you to change the Linux password after your initial setup To change your Linux password complete the followint steps 1 At t...

Page 53: ...Machine JVM and leverages OSGi a dynamic component system for Java to simplify the process of writing reusable software building blocks ESF APIs offer easy access to the underlying hardware including...

Page 54: ...ts l Leverage a device specific message oriented infrastructure for fast and easy creation of reliable device independent M2M IoT applications l Integrate MVNO Connectivity Platforms to have a single...

Page 55: ...nsions The ReliaGATE 10 05 34 electronics are housed in an ABS Color blue and Aluminum enclosure having the following dimensions 112 L x 68 W x 37 H mm antenna SMA connectors not included The followin...

Page 56: ...GATE 10 05 34 User Manual Rev 1 0 54 62 15 2 Mounting bracket mechanical dimensions The following figure shows the dimensions of the Mounting bracket All dimensions are in millimeters Figure 15 2 Moun...

Page 57: ...Kit to install the ReliaGATE 10 05 x4 on a DIN rail 16 1 How to install the ReliaGATE 10 05 34 using the Mounting Bracket To install the ReliaGATE 10 05 34 in place using the Mounting Bracket add all...

Page 58: ...aGATE 10 05 34 on a DIN rail replace the Mounting Bracket with the optional DIN Rail Mounting Kit 16 2 1 How to replace the Mounting Bracket with the DIN Rail Mounting Kit To replace the Mounting Brac...

Page 59: ...nual Rev 1 0 16 How to install the product 57 62 NOTE ABOUT THE 3 SCREWS The 3 screws that hold the Mounting Bracket in place have the following features l Cross socket flat head countersunk l Fully t...

Page 60: ...he lower mobile latches of the mechanical adapter on the lower edge of the DIN rail 2 Push the ReliaGATE 10 05 34 upwards against the DIN rail and lock upper latches of the mechanical adapter on the u...

Page 61: ...ction with wet hands Before starting the maintenance of the product complete the following steps 1 Remove the power supply 2 Disconnect all the cables 3 Make sure all the circuits are discharged Failu...

Page 62: ...This page has been intentionally left blank...

Page 63: ...ReliaGATE 10 05 34 User Manual Rev 1 0 Notes NOTES EUROTECH 61 62...

Page 64: ...EUROTECH Tel 33 0 4 72 89 00 90 Fax 33 0 4 78 70 08 24 Email sales fr eurotech com Email support fr eurotech com Web www eurotech com USA EUROTECH Tel 1 800 541 2003 Tel 1 301 490 4007 Fax 1 301 490...