background image

Instruction Manual MIXPRO 28                         EUROPRO                                        pag.23 

RESEARCH OF MALFUNCTIONS 

 

NR  ANOMALIES 

CAUSES  

SOLUTIONS 

The machine does 
not start. 

 

1) lack of power supply;  
2) lack of one phase.  

1) verify that the voltage is 400V-50Hz  

2) verify the connections of outlets and 

plugs, the status of fuses and electric 
panel protections of the machine and 
of the building site distribution panels 

 

The machine stops 
and the green war-
ning light blinks 
"Lack of water" 

 

 

1) insufficient water 
pressure;  
2) clogging of the water 
filter.  

1a) verify whether the water pump had 
been enabled;  
1b) verify the grip status of the pump 
fittings;  

2) extract the water filter and clean it, 

if necessary, replace it. 

 

The gearmotor 
does not start. 

 

1) gearmotor under 
stress;  
2) tap of the spraying 
nozzle closed;  
3) nozzle of the spraying 
nozzle clogged;  
4) material scaling in the 
mixing chamber;  

5) power supply plug not 
inser-ted. 

 

1) remove the power supply plug, open 
the mixing chamber and rotate the 
rotor to the right using the proper "T" 
wrench.  
In case of blocked rotor, replace it;  
2) open the tap of the spraying nozzle;  
3) carefully clean the nozzle of the 
spraying nozzle; 
4) disassemble the rotor / stator 
assembly and carefully clean the 
mixing chamber or ice; re- assemble 
the rotor / stator assembly;  
5) insert the power supply plug.  

The gearmotor 
stops- thermal 
protection tripping 

 

1) mixture too hard;  
2) use of a too long tube 
compa-red to the 
material used;  
3) use of not suitable 
mate-rials.  

1) perform the reset of the thermal  
switch tripping, (if  
necessary, request the technical service 
intervention) and re-start the machine 
with more water;  
2) reduce the length of the tube;  
3) verify the product data sheets.  

Th e c o m p r e s s 
o r stops ther-mal 
pro- tection 
intervention 

1) mechanical breaking 
of the compressor;  
2) intake filters blocked  
3) cables or plug 
damaged  

1) ask for technical assistance;  
2) replace the filters;  
3) check the cable and the plug and if 
necessary replace them;  

Water level in the 
mixing chamber is 
increasing.  

1) mixer blocked;  
2) mixer not enabled;  
3) excessive water flow 
rate;  
4) stator/rotor assembly 
tear.  

1a) verify that the mixer has been 
started;  
1b) verify the gearmotor power supply 
cable;  
1c) verify that the insertion of the 
outlet in the electric plug of the  
gearmotor;  
1d) insert the power supply plug;  
2) insert the mixer;  
3) reduce the water flow arte indicated 
on the flow meter acting on the adjust-
ment valve;  
electric panel .  
4) replace the assembly stator rotor.  

The water pump 
stops

thermal 

protection tripping  

1) Blocked pump  
2) Damaged cables and 
plug  

1) Reset intervention thermal ask any 
technical assistance interven-tion;  
2)check the cable and plug and replace 
any damaged parts  

Summary of Contents for MIXPRO 28

Page 1: ...RIGINAL INSTRUCTIONS Revision n of EUROPE PROJECTION Z I Rousset Parc Club 343 avenue Francis Perrin 13106 Rousset T l 00 33 0 4 42 29 08 96 Fax 00 33 0 4 42 53 44 36 SAS au capital de 400 000 SIREN 3...

Page 2: ...E 12 ASSEMBLING OF ROTOR AND MIXER 13 WATER CONNECTION 13 CONNECTION OF THE MATERIAL CONVEYING TUBE 14 CONNECTION OF THE MATERIAL CONVEYING AND AIR TUBES TO THE SPRAYING NOZZLE 14 ELECTRICAL CONNECTIO...

Page 3: ...nufacturer or the Authorized Dealer At the end of the testing the Manufacturer or Authorized Dealer fills in the testing and commissioning certificate which is signed by the testing technician the ope...

Page 4: ...Year of construction 2021 It s conformed to the following European Directives and the following modifications Directive 2006 42 CE recognize in Italy with D Lgs 17 2010 Machinery Directive Directive 2...

Page 5: ...0 v 50 Hz Water MORTAR 3 KW 230 v 50 Hz Water FLOOR SCREED 230 v 50 Hz Water Protection grade of switchboard IP44 Hopper capacity 70 litres Water pump flow rate 8 26 litres min Max served distance 40...

Page 6: ...Instruction Manual MIXPRO 28 EUROPRO pag 6 39 11 4 3 2 1 12 10 9 13 34 33 32 31 30 29 35 36 37 16 17 19 20 7 8 5 22 21 14 15 26 27 25 24 23 41 6 38 40 28...

Page 7: ...inlet in the mixing chamber all products except light ones 18 Water line pression guage 19 Bag cutting blade 20 Gearmotor power suppli plug 21 Compressor 22 Main power suppli plig 23 Command and cont...

Page 8: ...No 1 Air tube ext 19 mm L 16 m only for mod TOP No 1 Strike material conveying tube variable section L 20m mod EWI No 1 Air tube L 21 m mod EWI Components positioned in the tool carrying box No 1 Inst...

Page 9: ...ons of the regulations in force Separate the parts making up the machine according to the different construction materials plastic copper iron etc Lubricant liquids and any other fluids shall absolute...

Page 10: ...Instruction Manual MIXPRO 28 EUROPRO pag 10 MACHINE TRANSPORT In the drawing are visible the coupling points for the transport and handling of the machine...

Page 11: ...he machine is not suitable to use in environments with potentially explosive atmospheres Atex 8 Only one operator at time on the machine 9 The machine has not been conceived for to transport and or li...

Page 12: ...MEASURES Hopper protection grating Cutting hazard in case of contact with the bag cutting blade Education training Material conveying tube hazard to be hit by the ejection of material subject to pres...

Page 13: ...Instruction Manual MIXPRO 28 EUROPRO pag 13 ASSEMBLING OF ROTOR AND MIXER Carry out the operations by following the letters in succession WATER CONNECTION A B C E D A B...

Page 14: ...8 EUROPRO pag 14 CONNECTION OF THE MATERIAL CONVEYING TUBE Attention Performing the disconnection only in the absence of pressure indicated in gauge CONNECTION OF THE MATERIAL CONVEYING AND AIR TUBES...

Page 15: ...to power supply outlets of house systems Verify to provide voltage and power appropriate to the machine Verify that thermal magnetic circuit breaker protection and residual current protection life sa...

Page 16: ...erse run by hold action Up pos It reverse the mixer rotation direction mixer only with the machine in stopped status Down pos Return 5 Orange green red warning light Maxi LED for machine status self t...

Page 17: ...tion mixer only with the machine in stopped status 5 Orange green red warn ing light Maxi LED for machine status self test 6 Three position selector I Return 0 Start Stop Pos I It switches the machine...

Page 18: ...off 5 Make sure that the safety devices are integral properly installed and working 6 Make sure that the service taps and the system water drain are closed 7 Make sure that the valve of the spraying n...

Page 19: ...r 0 5 litres enter the mixing chamber 9 Open the water valve by pressing the blue button for at least 6 s 10 Loading of the product d Load the pre mixed products on the hopper cutting them at the bott...

Page 20: ...he spraying nozzle Adjust the spraying of the material moving forwards and or backwards or the air tube acting on the screw and blocking it in the correct position WORK BREAK 1 Stop the machine by clo...

Page 21: ...RIAL HOSE 1 Disconnect the material conveying tube to the connection pulling the side levers 2 Insert the into the material conveying tube the two foam rubber balls standard supplied 3 Insert the two...

Page 22: ...h water 2 Clean the air tube from any scaling using the specific brush supplied SWATER DRAINAGE DURING WINTER PERIOD 1 Disconnect the water inlet tubes of the machine and mixing chamber 2 Open the tap...

Page 23: ...or stator assembly 5 insert the power supply plug 4 The gearmotor stops thermal protection tripping 1 mixture too hard 2 use of a too long tube compa red to the material used 3 use of not suitable mat...

Page 24: ...t f r o m t h e spraying noz zle too liquid 1 excessive water flow rate 2 mixture scaling on the mixer 3 obstruction of the material output connection 1 reduce the water flow rate acting slow ly on th...

Page 25: ...products Replacement Every 30 40 hours of work Rotor screw stator plenum chamber used with gaseous products Replacement Every 100 150 hours of work Mixer Replacement Daily Safety devices Functional ve...

Page 26: ...form the manufacturer in case of defect detection immediately and in any case not later than 8 eight days from the detection date moreover it has to allow if deemed necessary by the same the performan...

Page 27: ...Instruction Manual MIXPRO 28 EUROPRO pag 27...

Page 28: ...28 Thank you for choosing our products Distribu par EUROMAIR DISTRIBUTION Rousset Parc Club 343 avenue Francis Perrin 13106 Rousset T l 00 33 0 4 42 29 08 96 Fax 00 33 0 4 42 53 44 36 SAS au capital d...

Reviews: