TThhee  eeyyeesshhaaddeess  ((ooppttiioonnaall))    
The eyepieces can be equipped with optional rubber eyeshades. They prevent damage to the eyepiece and prevent 
stray light. The eyeshade can simply be slipped over the eyepiece  
Connecting the power adapter   
 
The MicroBlue series supports a wide range of operating voltages: from 100 to 240V. Please use a grounded power 
connection  
 

1.

 

Make sure the power switch is off before connecting  

2.

 

Insert the connector of power cord into the MicroBlue power socket, and make sure it connects well  

3.

 

Insert the other connector of the adapter into the mains socket, and make sure it connects well 

  
D

Doo  nnoott  bbeenndd  oorr  ttw

wiisstt  tthhee  ppoow

weerr  ccoorrdd,,

 it will be damaged. Use the power cord that is supplied by Euromex. If it is lost or 

damaged, choose one with the same specifications 

Operation  

Setting up the illumination:  

For optimal contrast and resolution one should follow the 
procedure below:  

A.

 

Place a specimen on the object stage and focus, using the 
4x objective, with a fully opened iris diaphragm  

B.

 

Turn light intensity to lowest position, then look through 
the eyepiece(s) and turn up to the comfortable light 
intensity level  

C.

 

Turn the condenser in the highest position  

D.

 

Close the iris diaphragm, until it is just visible on the edge 
of the field of view 

 
The microscope is properly set for use with the 4x objective. For 
each other magnification in bright field use, this procedure should be repeated to ensure the best balance between 
contrast and resolution 

 

CCaauuttiioonn

:  

The maximum light intensity when using the 4x and 10x can damage the eyes!

 

 

8

Summary of Contents for BlueLine Series

Page 1: ...D U T C H Q U A L I T Y MicroBlue BlueLine series user manual...

Page 2: ...e ratio Please read this manual carefully before using this product to ensure correct and safe usage The contents of this manual are subject to change without notice The appearance of the actual produ...

Page 3: ...de protection 9 Eyepieces 9 1 The interpupillary distance 9 2 The correct eye point 9 3 Adjusting the diopter 10 Abbe condenser 10 Use of the S100x oil immersion objective 10 Safety device 11 Illumina...

Page 4: ...e of the lens regularly Cleaning optical components is a delicate matter Please read the cleaning instructions in this manual carefully E En nv vi ir ro on nm me en nt t s st to or ra ag ge e a an nd...

Page 5: ...widefield eyepieces WF10x H and Achromatic objectives as mentioned below table P Pl le ea as se e n no ot te e On www euromex com you can find the latest updates about MicroBlue models and accessories...

Page 6: ...E Tension adjustment M Object stages mechanical stage or clips F On Off switch not visible N Height adjustment lever condenser G Light intensity control O Condenser with irisdiaphragm filterholder H...

Page 7: ...es into the objective nosepiece from the lowest magnification to the highest in a clockwise direction from the rear side of the microscope When using the microscope start using the low magnification o...

Page 8: ...co or rd d it will be damaged Use the power cord that is supplied by Euromex If it is lost or damaged choose one with the same specifications Operation Setting up the illumination For optimal contras...

Page 9: ...e mechanical stage This way the objectives will not touch or break your slides In case a standard version is purchased including a S100x objective this is pre set at the factory Eyepieces A binocular...

Page 10: ...rews using an allen key and move the image of the condenser ring to the center of the field of view F Open the diaphragm gradually G The condenser is centered correctly if the image remains in the cen...

Page 11: ...scope with power supply disconnected to keep the batteries in good working condition and recharge after batteries run empty The illumination has the following specifications LED NeoLED 1W 300 mA monoc...

Page 12: ...earings that are not dust sensitive With a drop of sewing machine oil you can lubricate the bearing Changing the batteries of the MicroBlue C Ca au ut ti io on n Always remove the power cable from the...

Page 13: ...esigned to be used on the photo port of the microscope head It is also possible to use the digital camera in combination with a monocular or binocular head Simply remove the eyepiece and place the cam...

Page 14: ...re parts For current accessories and spares please check our website www euromex com Trinocular MicroBlue head with mounted camera in photo port Monocular MicroBlue microscope with camera replacing th...

Page 15: ...15 Notes 15...

Page 16: ...bv Papenkamp 20 6836 BD Arnhem The Netherlands T 31 0 26 323 22 11 info euromex com www euromex com Management System ISO 9001 2015 www tuv com ID 0000037140 All information may be changed without pr...

Reviews: