background image

 

Notes on handling and Safety  

H

Haannddllee  w

wiitthh  ccaarree    

 

This product is a high quality optical instrument. Delicate handling is required  

 

Avoid subjecting it to sudden shocks and impacts  

 

Impacts, even small ones, can affect the precision of the objective  

 
H

Haannddlliinngg  tthhee  LLEED

D    

N

Noottee::

 Always disconnect the power cord from your microscope before handling the LED bulb and power unit and allow 

the system approximately 35 minutes to cool down to avoid burns  

 

Never touch the LED with your bare hands  

 

Dirt or fingerprints will reduce the life span and can result in uneven illumination, lowering the optical 
performance  

 

Use only Euromex original replacement LEDs  

 

Use of other products may cause malfunctions and will void warranty  

 

During use of the microscope, the power unit will get hot; never touch it while in operation and allow the 
system approximately 35 minutes to cool down to avoid burns  

  
D

Diirrtt  oonn  tthhee  lleennsseess    

 

Dirt on, or inside the optical components, such as eyepieces, lenses, etc., affects the image quality of your 
system negatively  

 

Always try to prevent your microscope from getting dirty by using the dust cover, prevent leaving fingerprints 
on the lenses and clean the outer surface of the lens regularly  

 

Cleaning optical components is a delicate matter. Please read the cleaning instructions in this manual carefully  

  
EEnnvviirroonnm

meenntt,,  ssttoorraaggee  aanndd  uussee    

 

This product is a precision instrument and it should be used in a proper environment for optimal use  

 

Install your product indoors on a stable, vibration free and level surface  

 

Do not place the product in direct sunlight  

 

The ambient temperature should be between 5 to +40°C and humidity is maximum 80% at 31 degrees 
decreasing linearly to 50% at 40 degrees. Although the system is anti-mold treated, installing this product in a 
hot, humid location may still result in the formation of mold or condensation on lenses, impairing performance 
or causing malfunctions  

 

Never turn the right and left focus knobs in opposite directions at the same time or turn the coarse focus knob 
past its farthest point, this will damage the microscope  

 

Never use undue force when turning the knobs  

 

Make sure that the microscope system can dissipate its heat  

 

Keep the microscope approximately 15 cm free from walls and obstructions  

 

Never turn the microscope on when the dust cover is in place or when items are placed on the microscope  

 

Keep flammable fluids, fabric etc. well out of the way  

 
D

Diissccoonnnneecctt  ppoow

weerr    

 

Always disconnect your microscope from power before doing any maintenance, cleaning, assembling or 
replacing LEDs to prevent electric shocks  

 
 
 

 

PPrreevveenntt  ccoonnttaacctt  w

wiitthh  w

waatteerr  aanndd  ootthheerr  fflluuiiddss    

 

Never allow water or other fluids to come in contact with your microscope, this can cause short circuiting your 
device, causing in turn malfunction and damage on your system  

 
M

Moovviinngg  aanndd  aasssseem

mbblliinngg    

 

The MicroBlue microscope is a relatively heavy system, consider this when moving and installing the system  

 

Always lift the microscope by holding the main body and base of the microscope  

 

Never lift or move the microscope by its focusing knobs, stage or head  

 

When needed, move the microscope with two persons instead of one  

Models  

The EUROMEX MicroBlue range microscopes are standard equipped with 1 or 2 widefield eyepieces WF10x (H) and 
Achromatic-objectives, as mentioned below table  
 

PPlleeaassee  nnoottee::

 On www.euromex.com you can find the latest updates about MicroBlue models and accessories 

 

M O D E L S  

Mono  Bino  Trino  Maximum 

objectives 

4/10/S40x 

objectives 

S60x  

objective 

S100x  

objective 

Mechanical 

X-Y stage 

LED  

NeoLED  

Batteries 

MB.1001  

• 

 

 

• 

 

 

 

• 

 

• 

MB.1051 

• 

 

 

• 

 

 

• 

• 

 

• 

MB.1651 

• 

 

 

• 

• 

 

• 

• 

 

• 

MB.1151 

• 

 

 

• 

 

• 

• 

• 

 

• 

MB.1052 

 

• 

 

• 

 

 

• 

 

• 

• 

MB.1652 

 

• 

 

• 

• 

 

• 

 

• 

• 

MB.1152 

 

• 

 

• 

 

• 

• 

 

• 

• 

MB.1053 

 

 

• 

• 

 

 

• 

 

• 

• 

MB.1653 

 

 

• 

• 

• 

 

• 

 

• 

• 

MB.1153 

 

 

• 

• 

 

• 

• 

 

• 

• 

 
The S40x, S60x and S100x objectives are equipped with a spring mount, to prevent damage to the front lens and the 
slide. The Numeric Aperture - N.A. – of the objective is an indication for the resolving power of the objective. The total 
magnification can be calculated by multiplying the magnification of the eyepiece with the magnification of the objective. 
The magnifications are displayed in the table below: 
 
 

 

Eyepiece 

Objective 

Magnification 

10x 

4x 

40x 

10x 

10x 

100x 

20x 

20x 

400x 

 

10x 

40x 

400x 

10x 

60x 

600x 

10x 

100x 

1000x 

 

 

5

Summary of Contents for BlueLine Series

Page 1: ...D U T C H Q U A L I T Y MicroBlue BlueLine series user manual...

Page 2: ...e ratio Please read this manual carefully before using this product to ensure correct and safe usage The contents of this manual are subject to change without notice The appearance of the actual produ...

Page 3: ...de protection 9 Eyepieces 9 1 The interpupillary distance 9 2 The correct eye point 9 3 Adjusting the diopter 10 Abbe condenser 10 Use of the S100x oil immersion objective 10 Safety device 11 Illumina...

Page 4: ...e of the lens regularly Cleaning optical components is a delicate matter Please read the cleaning instructions in this manual carefully E En nv vi ir ro on nm me en nt t s st to or ra ag ge e a an nd...

Page 5: ...widefield eyepieces WF10x H and Achromatic objectives as mentioned below table P Pl le ea as se e n no ot te e On www euromex com you can find the latest updates about MicroBlue models and accessories...

Page 6: ...E Tension adjustment M Object stages mechanical stage or clips F On Off switch not visible N Height adjustment lever condenser G Light intensity control O Condenser with irisdiaphragm filterholder H...

Page 7: ...es into the objective nosepiece from the lowest magnification to the highest in a clockwise direction from the rear side of the microscope When using the microscope start using the low magnification o...

Page 8: ...co or rd d it will be damaged Use the power cord that is supplied by Euromex If it is lost or damaged choose one with the same specifications Operation Setting up the illumination For optimal contras...

Page 9: ...e mechanical stage This way the objectives will not touch or break your slides In case a standard version is purchased including a S100x objective this is pre set at the factory Eyepieces A binocular...

Page 10: ...rews using an allen key and move the image of the condenser ring to the center of the field of view F Open the diaphragm gradually G The condenser is centered correctly if the image remains in the cen...

Page 11: ...scope with power supply disconnected to keep the batteries in good working condition and recharge after batteries run empty The illumination has the following specifications LED NeoLED 1W 300 mA monoc...

Page 12: ...earings that are not dust sensitive With a drop of sewing machine oil you can lubricate the bearing Changing the batteries of the MicroBlue C Ca au ut ti io on n Always remove the power cable from the...

Page 13: ...esigned to be used on the photo port of the microscope head It is also possible to use the digital camera in combination with a monocular or binocular head Simply remove the eyepiece and place the cam...

Page 14: ...re parts For current accessories and spares please check our website www euromex com Trinocular MicroBlue head with mounted camera in photo port Monocular MicroBlue microscope with camera replacing th...

Page 15: ...15 Notes 15...

Page 16: ...bv Papenkamp 20 6836 BD Arnhem The Netherlands T 31 0 26 323 22 11 info euromex com www euromex com Management System ISO 9001 2015 www tuv com ID 0000037140 All information may be changed without pr...

Reviews: