– The product is intended for room temperatures of
5–35 °C.
– Leave the product to stabilise for a few minutes
after installation.
Operation
Check before switching on!
Check the safe condition of the product:
– Check whether there are any visible defects.
– Check whether the condensate tank is empty.
– Ensure that the condensate tank is correctly
inserted.
Functions
The product operates according to the condensation
principle.
•
The fan sucks in the humid room air through the
intake filter.
•
The room air is cooled to below the dew point and
the water vapour contained in the air precipitates
as condensate.
•
The dehumidified, cooled air is then warmed
back up and blown out again at a temperature a
few degrees above room temperature.
Humidity Level & Timer 2 Digital Display
•
When the unit is turned on, it will indicate the
room humidity level.
•
When you set the humidity, it will indicate the
humidity that you have selected
•
When you program the time for the unit to turn on
and off, it will show the hours.
•
When the environment humidity is lower than
35%, it will show
[35]
•
When the environment humidity is higher than
95%, it will show
[95]
Operating Instructions
The buzzer will alarm when the unit is powered on,
the LED will show the room humidity, then it will auto-
matically turn off.
Turn on/off
– Press
[ ]
to turn on or turn off the unit
Humidity setting
– Press the
[
]
key to enter humidity-setting state,
then press
[
]
or
[
]
to adjust the humidity
from 40% to 80%, at 5% interval. The default
value of humidity is 40%.
Fan-speed setting
– Press
[
]
to set the fan speed to high or low, and
the corresponding fan speed light will be lighted.
Swing setting
– After the machine is started, press
[
]
to start or
stop the air-outlet leaf ’swing.
Time-setting
– Press
[
]
to enter boot-time setting state to set
when the unit will be off, then the LED will display
the time, press
[
]
or
[
]
button to adjust the
automatic boot time from 1 to 24 hours.
– When the unit is operating, press
[
]
to enter
shutdown-time setting state to set when the unit
will be shut down, then the LED will display the
time, press
[
]
or
[
]
button to adjust the auto-
matic shutdown time from 1 to 24 hours.
Draining The Collected Water
When the drainage tank is full, the tank full indicator
light will flash, the operation will stop automatically
and the buzzer will alarm to alert the user, that the
water need to be emptied from the drainage tank.
Emptying the Drainage Tank
– Lightly press on the sides of the tank with both
hands and pull the tank out gently.
– Discard the collected water
Note
•
If the drainage tank is dirty, wash it with cold or
lukewarm water. Do not use detergent, scouring
pads, chemically treated dust cloths, gasoline,
benzene, thinner, or other solvents, as these can
scratch and damage the tank and cause water
leakage
•
When replacing the drainage tank, press the tank
firmly into place with both hands. If the tank is not
positioned properly, the
[TANK FULL]
sensor will
be activated, and the dehumidifier will not oper-
ate.
Continuous Water Drainage
The unit features a continuous drainage port. Using a
plastic pipe (with an inner diameter of 10mm) inserts
into drain hole (on intermediate plate), reach out from
side of water tank, install it in place, and arrange the
drain pipe.
The water in the drainage tank can be continuously
drained out from the continuous port on the unit.
Cleaning and maintenance
To clean the Body
– Wipe it with a soft damp cloth.
To Clean the Air Filter
– Open the inlet grill firstly and remove the air filter
– Clean the air filter
– Run a vacuum cleaner lightly over the surface of
the air filter to remove dirt. If the air filter is excep-
tionally dirty, wash it with warm water and a mild
cleanser and dry thoroughly.
DANGER! Risk of injury!
The product
may only be put into operation if no faults
are found during the check-up. It is crucial
that any defective parts are replaced before
the product is used again.
Note:
At room temperatures below 5 °C and
a relative humidity below 35%, economic
product output is no longer guaranteed.
The indicator features 3 functions:
DANGER! Risk of injury!
Always pull the
mains plug out before commencing any
work on the device.
Summary of Contents for LEF-260-55
Page 1: ...LEF 260 55 107596 DE Luftentfeuchter GB Dehumidifier PL Osuszacz powietrza...
Page 2: ...2 bersicht Overview Przegl d 1 2...
Page 3: ...3 Inbetriebnahme Commissioning Uruchomienie 1...
Page 4: ...4 Bedienung Operation Obs uga 1 2 3...
Page 5: ...5 Wartung Maintenance Konserwacja 4 1 2...
Page 6: ...6 3 4 5...
Page 22: ...22...
Page 23: ...23...