Faults and remedial measures
When something isn’t working…
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Please
consult the following table before contacting the ven-
dor. You will save yourself a lot of trouble and possi-
bly money too.
If you can’t fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
Disposal
Disposal of the appliance
A crossed-out wheelie bin icon means: Bat-
teries and rechargeable batteries, electrical
or electronic devices must not be disposed of
with household waste. They may contain
substances that are harmful to the environ-
ment and human health.
Consumers must dispose of waste electrical devices,
spent portable batteries and rechargeable batteries
separately from household waste at an official collec-
tion point to ensure that these items are processed
correctly. Information on returning these items is
available from the seller. Sellers are required to
accept these items free of charge.
Batteries and rechargeable batteries, which
are not permanently installed in waste elec-
trical devices, must be removed prior to dis-
posal and must be disposed of separately.
Lithium batteries and battery packs in all systems
must only be retuned to a collection point when dis-
charged. Batteries must always be protected against
short circuits by covering the poles with adhesive
tape.
All end users are responsible for deleting any per-
sonal data stored on waste devices prior to their dis-
posal.
Disposal of the packaging
The packaging consists of cardboard and
correspondingly marked plastics that can
be recycled.
– Make these materials available for
recycling.
Technical data
Information requirements for electric local space heaters
DANGER! Risk of injury!
Improperly per-
formed repairs can lead to the device not
functioning safely. This endangers yourself
and your environment.
Fault/malfunc-
tion
Cause
Remedial measure
Device does not
heat.
Is the device switched off?
Switch on the device or set the desired heat
level.
Is the temperature regulator (3) set too low?
Set the temperature regulator higher.
No mains voltage?
Check cables, plugs, outlets and fuse.
Blower is not
working.
Is the blower not switched on?
Switch on blower.
No mains voltage?
Check cables, plugs, outlets and fuse.
Item number
107434
Nominal voltage
230 V~, 50 Hz
Nominal output
2000 W
Heat levels
750 W
1250 W
2000 W
Protection class
I
Dimensions
53 × 20 × 37,8 cm
Model identifier(s):
107434
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local
space heaters only
Nominal heat output P
nom
1,8-2,0
kW
manual heat charge control, with integrated
thermostat
[no]
Minimum heat out-
put (indicative)
P
min
0,75
kW
manual heat charge control with room and/
or outdoor temperature feedback
[no]
Maximum continu-
ous heat output
P
max,c
2,0
kW
electronic heat charge control with room
and/or outdoor temperature feedback
[no]
Auxiliary electricity consumption
fan assisted heat output
[no]